SECTION 5. TELECOMMUNICATIONS
TABLE 5.1-1 Telecommunications Commands
5-3
[F.S. Area]
A
SELECT AREA/STATUS
- If 1 or 2 does not precede the A to select the Final
Storage Area, the CR10X defaults to Area 1. All subsequent commands other
than A will address the area selected. Datalogger returns
R
eference (the DSP
location); the number of filled
F
inal Storage locations;
V
ersion of datalogger;
Final Storage
A
rea;
L
ocation of MPTR (the location number may be 1 to 7
characters long);
E
rrors #1, #2 and #3 where #1 is the number of E08s, #2 is
the number of overrun errors and #3 is the number of times the program
stopped due to low voltage (all are cleared by entering 8888A; #2 is also
cleared at time of program compilation); size of total
M
emory in CR10X; the
lithium
B
attery voltage; and
C
hecksum. All in the following format:
R+xxxxx F+xxxxx Vxx Axx L+xxxxxxx Exx xx xx Mxxxx B+xxxxx Cxxxx
If data is stored while in telecommunications, the A command must be re-
issued to update the Reference to the new DSP.
[no. of arrays]
B
BACK UP
- MPTR is backed up the specified number of Output Arrays (no
number defaults to 1) and advanced to the nearest start of array. CR10X sends
the Area, MPTR Location, and Checksum: Ax L+xxxxxxx Cxxxx
[YR:DAY:HR:MM:SS]
C
RESET/SEND TIME
- If time is entered the time is reset. If only two colons are
in the time string, HR:MM:SS is assumed; three colons means DAY:HR:MM:SS.
If only the C is entered, time is unaltered. CR10X returns year, Julian day,
hr:min:sec, and Checksum: Y:xx Dxxxx Txx:xx:xx Cxxxx
[no. of arrays]
D
ASCII DUMP
- If necessary, the MPTR is advanced to the next start of array.
CR10X sends the number of arrays specified (no number defaults to 1) or the
number of arrays between MPTR and Reference (whichever is smaller), CRLF,
Location, Checksum.
E
END CALL
- Datalogger sends CRLF only.
[no. of loc.]
F
BINARY DUMP
- Used by Campbell Scientific Datalogger Support Software for
data retrieval. See Appendix C.
[F.S. loc. no.]
G
MOVE MPTR
- MPTR is moved to specified Final Storage location. The
location number must be entered. CR10X sends Area, Location, and
Checksum: Ax L+xxxxxxx Cxxxx
7H
or
2718H
REMOTE KEYBOARD STATE
- CR10X sends the prompt ‘>’ and is ready to
execute standard keyboard commands. See Section OV3.
[loc. no.]I
DISPLAY/CHANGE INPUT STORAGE
- CR10X sends the value stored at the
location. A new value and CR may then be sent. CR10X sends checksum. If no
new value is sent (CR only) the location value remains the same.
3142J
TOGGLE FLAGS AND SET UP FOR K COMMAND
- Used in the Monitor
Mode and with the Heads Up Display. See Appendix C for details.
2413J
SET UP FOR K COMMAND
- Used in the Monitor Mode and with the Heads
Up Display. Similar to the 3142J command, but does not toggle flags and ports.
See Appendix C for details. (Available first in CR10X OS Version 1.10; also
indicated by ‘V4’ returned to the A command – see above.