CPEC300/306/310 Closed-Path Eddy-Covariance Systems
73
TABLE 6-12. Data fields in the Flux_Notes Output Table
Data Field Name
Units
Description
Data Field
Included
pump_fan_secs
s
Number of seconds in the interval that
the pump fan was on
Always
valve_tmpr
deg C
Average temperature of the valve
module
If the system
has a valve
module (i.e.
CPEC310)
valve_heater_secs
s
Number of seconds in the interval the
valve module heater was on
If the system
has a valve
module (i.e.
CPEC310)
valve_fan_secs
s
Number of seconds in the interval the
valve module fan was on
If the system
has a valve
module (i.e.
CPEC310)
scrub_tmpr
deg C
Average temperature of the scrub
module
If the system
has a scrub
module
scrub_press
kPa
Average pressure of the scrub module
If the system
has a scrub
module
scrub_heater_secs
s
Number of seconds in the interval that
the scrub module heater was on
If the system
has a scrub
module
scrub_fan_secs
s
Number of seconds in the interval that
the scrub module fan was on
If the system
has a scrub
module
cell_tmpr
deg C
Average temperature of the sample cell
Always
cell_tmpr_SIGMA
deg C
Standard deviation of the sample cell
temperature
Always
cell_press
kPa
Average pressure inside the sample cell
Always
cell_press_SIGMA
kPa
Standard deviation of the sample cell
pressure
Always
diff_press
kPa
The differential pressure; that is, the
difference in pressure between the
sample cell and ambient
Always
pump_flow
L·min-1
Average volumetric flow to pump (sum
of sample flow and vortex bypass flow)
Always
pump_flow_SIGMA
L·min-1
Standard deviation of pump flow
Always
cell_e
kPa
Average vapor pressure in sample cell
Always
cell_T_DP
Deg C
Average dew point temperature inside
sample cell
Always
cell_e_sat
kPa
Average saturation vapor pressure
inside sample cell
Always