CPEC300/306/310 Closed-Path Eddy-Covariance Systems
38
Press
Esc
on the CR1000KD keypad at any time to return to the
previous menu or screen.
Using LoggerNet
The constants may be edited using LoggerNet software on a PC. Use the
LoggerNet
Connect Screen
to connect to the datalogger, and then use the Table
Monitor to view the table called
Const_Table.
To edit a value, click on the cell
to the right of the constant name, enter the new value, and press
Enter.
Once
all new values are entered, scroll to the bottom of the
Const_Table
and change
the value of
ApplyAndRestart
from
FALSE
to
TRUE
and press
Enter.
The
software may lose connection with the datalogger while the program is
recompiled. Connect again and view the table again to verify the new values
were saved. Once this is done, the user is ready to set site-specific variables;
(p. 43)
Using CRBasic Editor
The constants may be edited by opening the program in CRBasic Editor. Find
the constants near the top of the program code, just after the introductory
comments in a section titled “USER-DEFINED CONFIGURATION
CONSTANTS” (see FIGURE
); a user may also search for the word
“unique” to find lines of code with user-editable constants.
Once changes are completed, the program must be recompiled and saved. Save
the program under a new or modified file name to keep track of different
program versions. Finally, send the program to the CR6 using
LoggerNet
,
PC400
, or
PC200W
user-interface software. After sending the program, its
site-specific variables are ready to be reviewed and edited; see Section
(p. 43)
.
NOTE