background image

CPEC200

  

Closed Path  

Eddy Covariance System  

 

Quickstart Guide 

 

 

 

 

 

 

 

 

 

December 2011 

 

 

 

 

 

 

Summary of Contents for CPEC200

Page 1: ...CPEC200 Closed Path Eddy Covariance System Quickstart Guide December 2011...

Page 2: ...1 Setup tripod and mount enclosures CPEC200 Enclosure EC100 Enclosure Pump Module...

Page 3: ...2 Ground tripod and enclosures Ground Lug Grounding Rod...

Page 4: ...3 Setup tripod or mast with CM20X Crossarm Crossarm To Pole Bracket CM20X Crossarm...

Page 5: ...4 Mount gas analyzer and sonic anemometer EC155 Gas Analyzer CM20X Crossarm EC155 Boom Adapter Mounting Platform CSAT3A Sonic Anemometer Head Leveling Bubble...

Page 6: ...5 Connect EC155 and CSAT3A to EC100 Electronics EC155 Analyzer Cable EC155 Sample Cell Cable CSAT3A Cable...

Page 7: ...6 Connect system plumbing Zero Air Tubing Analyzer Tubing Pump Tubing Pump Module Cable CO2 Span Gas Tubing...

Page 8: ...7 Connect system wiring and insert compact flash CF card EC100 Power and SDM Cables System Power Cable ensure 12 Vdc power supply is off Insert CF Card...

Page 9: ...Power Cable to EC100 EC100 SDM Cable Power Cable to 12Vdc Power Supply off SDM Cable to EC100 EC100 Power Cable...

Page 10: ...to right top to bottom System Control Sonic Azmth 0 00000 Change Press Source Mode EC_off_auto_zro On Site Zero Span View Data Dfl Tub Dly 1 00000 System Menu Select Sonic Azmth Press Esc to activate...

Page 11: ...Control Sonic Azmth 150 000 Change Press Source Mode EC_off_auto_zro On Site Zero Span View Data Dfl Tub Dly 1 00000 System Menu If your CPEC200 does not have a valve module skip to the last step Oth...

Page 12: ...On Site Zero Span Span Concentrations Do Zero False Do CO2 Span False Do H2O Span False Select the Span Concentrations menu Select CO2 Span Concentrations CO2 0 00000 Td 10 0000...

Page 13: ...c twice to return to the System Control menu Select the Mode menu System Control Sonic Azmth 150 000 Change Press Source Mode EC_off_auto_zro On Site Zero Span View Data Dfl Tub Dly 1 00000 System Men...

Page 14: ...uto_zro_spn Ambient_press Zero_all Span_CO2_1 Span_CO2_2 Span_CO2_3 Span_CO2_4 Select EC_on_auto_zro_spn Press Esc to exit Campbell Scientific CR3000 Datalogger 12 02 2011 14 00 08 4 CPU CPEC200_vx_x...

Page 15: ......

Page 16: ...Please visit www campbellsci ca to obtain contact information for your local Canadian or International representative...

Reviews: