CNR4 Net Radiometer
15
TABLE 7-1. SOLAR Cable (Wire Color, Function, and Datalogger Connection)
Wire
Color
Wire Function
Differential Datalogger Connection
Terminal
Single-Ended Datalogger
Connection Terminal
Red
Pyranometer Top
Signal
U
configured for differential input
1
,
DIFF H
(differential high, analog-
voltage input)
U
configured for single-ended analog
input
1
,
SE
(single-ended, analog-
voltage input)
Blue
Pyranometer Top
Reference
U
configured for differential input
1, 2
,
DIFF L
(differential low, analog-
voltage input)
2
AG or
⏚
(analog ground)
White
Pyranometer
Bottom Signal
U
configured for differential input
1
,
DIFF H
(differential high, analog-
voltage input)
U
configured for single-ended analog
input
1
,
SE
(single-ended, analog-
voltage input)
Black
Pyranometer
Bottom Reference
U
configured for differential input
1, 2
,
DIFF L
(differential low, analog-
voltage input)
2
AG or
⏚
(analog ground)
Grey
Pyrgeometer Top
Signal
U
configured for differential input
1
,
DIFF H
(differential high, analog-
voltage input)
U
configured for single-ended analog
input
1
,
SE
(single-ended, analog-
voltage input)
Yellow
Pyrgeometer Top
Reference
U
configured for differential input
1, 2
,
DIFF L
(differential low, analog-
voltage input)
2
AG or
⏚
(analog ground)
Brown
Pyrgeometer
Bottom Signal
U
configured for differential input
1
,
DIFF H
(differential high, analog-
voltage input)
U
configured for single-ended analog
input
1
,
SE
(single-ended, analog-
voltage input)
Green
Pyrgeometer
Bottom Reference
U
configured for differential input
1, 2
,
DIFF L
(differential low, analog-
voltage input)
2
AG or
⏚
(analog ground)
Clear
Shield
AG or
⏚
(analog ground)
AG or
⏚
(analog ground)
1
U
channels are automatically configured by the measurement instruction.
2
Jumper to AG or
⏚
with a user-supplied wire.
TABLE 7-2. TEMP Cable
1
(Wire Color, Function, and Datalogger Connection)
Wire Color
Wire Function
Datalogger Connection Terminal
White
Thermistor Signal
U
configured for single-ended analog input
2
,
SE
(single-ended, analog-voltage input)
Red
Thermistor Voltage Excitation
U
configured for voltage excitation
2
,
EX
,
VX (
voltage excitation)
Black
Thermistor Reference
AG or
⏚
(analog ground)
Clear
Shield
AG or
⏚
(analog ground)
1
Pull back wires for Pt-100 (grey, brown, green, and yellow), which are not in use, and tie them around the
TEMP
cable
using a cable tie or electrical tape to avoid possible damage to the Pt-100, due to electrical short circuit.
2
U
channels are automatically configured by the measurement instruction.
Summary of Contents for CNR4
Page 2: ......
Page 6: ......
Page 10: ...Table of Contents iv ...
Page 36: ...CNR4 Net Radiometer 26 ...
Page 38: ......
Page 52: ...Appendix B Example Programs B 14 ...
Page 68: ...Appendix D CNF4 Heater Ventilator D 12 ...
Page 69: ......