Select Settings then Advanced tab. Enter your trusted IP addresses, one per line, in the
Trusted IP Host Addresses box.
9. (Optional, for modules with static IP addresses.) To get remote access to the module you
must first set up a User Account. For security purposes there is no default account. Select
Settings > User Accounts > Logon > Create a new Account. Provide Name, Password, and
select the Permission Level. Close then Apply Changes.
Once the module has an account it can be accessed remotely using its static IP address.
Type the IP address into a web browser to be prompted for the user name and password.
6.4.2.2 Configure data logger
1. Connect to your data logger using Device Configuration Utility.
2. If using the Konect PakBus Router:
a. On the Datalogger tab, change the data logger PakBus Address and optional
PakBus/TCP Password to match the values entered in the Konect PakBus Router
setup.
b. On the Network Services tab in the PakBus/TCP Client field, enter the DNS address
and Port number noted during the Konect PakBus Router setup.
CELL200-Series 4G LTE Cellular Module
32