4.2.4 Test the connection
After the Network Map has been configured, test the cellular connection by using the Connect
screen as shown in the following image. Click on the appropriate station and click Connect to
initiate a call to the data logger.
TIP:
The connection time is subject to many external factors. It is often less than 30 seconds but
could be up to fifteen minutes. Be patient.
If the call is successful, the connectors at the bottom of the screen will come together and clock
information from the data logger will be displayed in the Station Date/Time field. If the
connection fails, a Communications Failure message will be displayed.
5. Specifications
Data Logger Compatibility
The CELL200 series is compatible with the CR1000X, CR300 series, CR6 series, CR1000, CR3000,
CR800 series, CR200(X) series, CR5000, CR10X, CR10X-PB, CR510, CR510-PB, CR23X, and
CR23X-PB. See
Module communications connections
(p. 25) for information on communication
options with each data logger model.
CELL200-Series 4G LTE Cellular Module