l
Serial Client: Use this mode when the module is behind a cellular provider firewall and it
has a private dynamic IP address. In serial client mode the module will connect to the
cellular network and initiate a TCP client socket connection.
l
Serial Server/Client: In serial server/client mode the module connects to the cellular
network and opens a listening port. When a client connects to the listening port, the
CELL200 series will be in "Serial Server" mode, as described earlier. When no client is
connected to the listening port, the CELL200 series will be in "Serial Client" mode, as
described earlier, and all data on the active port will be sent and received through the
initiated TCP client socket connection.
Data loggers compatible with each mode are shown in the following table.
Integrated
PPP
Non-
integrated
PPP
Serial
server
2
Serial
client
3
Serial
server/
client
3
CR6 series/CR1000X/
CR300 series
1
✔
✔
✔
✔
✔
CR1000/CR3000/CR800 series
✔
✔
✔
✔
CR200(X) series
✔
✔
✔
Array-based
(Edlog) data loggers
✔
✔
✔
1
Integrated PPP mode requires operating system 03.00 or later for the CR1000X, 09.00 or greater for the CR6
series, and 08.00 or later for the CR300 series.
2
Serial server mode requires a public static IP account.
3
Requires CELL200 series OS 2.00 or later.
4. QuickStart (integrated mode)
NOTE:
This QuickStart describes configuring the CELL200 series in integrated mode (mimicking our
internal cell modems) with its default settings. It can also be configured in non integrated or
serial server mode.
This QuickStart section does not apply to CR3000, CR1000 and CR800-series users. See
(p. 7) for more information on the different modes. See
CELL200-Series 4G LTE Cellular Module
8