Appendix D. The Public Table
Control Parameters When Troubleshooter is Running
TimeSeries(1)
Writing this variable will force a Vibrating Wire
measurement and create the TimeSeries.bin and
spectrum.bin files.
Example:
101 = measures AVW200 chan1 and Mux chan1
102 = measures AVW200 chan1 and Mux chan2
.....
201 = measures AVW200 chan2 and Mux chan1
202 = measures AVW200 chan2 and Mux chan2
....
232 = measures AVW200 chan2 and Mux chan32
Notes: TimeSeries(2)..(4) need to be filled with valid values
before making the measurement.
TimeSeries(2)
Begin Frequency for force measurement (100 - 6500)
TimeSeries(3)
Eng Frequency for forcing measurement (100 - 6500)
TimeSeries(4)
Excite voltage for forcing measurement (1=5volts or
2=12volts)
TimeSeries(5)
Copy of the Chan/MuxChan executed in TimeSeries(1)
TimeSeries(6)
Measured Frequency (Hz)
TimeSeries(7)
Measured Amplitude (MVolts_RMS)
TimeSeries(8) Measured
Signal-to-Noise
Ratio
TimeSeries(9)
Measured Noise Freq (Hz)
TimeSeries(10) Measured
Decay
Ratio
TimeSeries(11) Measured Thermistor (ohms)
D-3
Summary of Contents for AVW200 series
Page 2: ......
Page 78: ...Appendix C Antennas Antenna Cables and Surge Protectors for the AVW206 AVW211 and AVW216 C 8...
Page 86: ...Appendix E Status Table E 4...
Page 104: ...Appendix H Additional Programming Examples H 12...
Page 110: ...Appendix I Using MD485 Multidrop Modems with AVW200 Interfaces I 6...
Page 111: ......