AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules
When using the “Mcmm” terminal command, no other
method of measurement should be used or multiplexing
will get out of sequence and measurement errors will
result.
CAUTION
Read more! Appendix D. lists the fields in the public table and provides a
brief description of each. Appendix E. provides a comprehensive list of
status table variables with brief descriptions.
6. Programming
6.1 AVW200 Instruction
If using SDI-12 to communicate with the AVW200, then use the
SDI12Recorder instruction to trigger and retrieve measurements
from the AVW200 (see Section 6.2.)
NOTE
When using the RS-232 (PakBus) or RF(PakBus) protocol, the datalogger is
programmed using the AVW200 instruction in CRBasic.
Please ensure that the AVW200 instruction is included in
LoggerNet. If using LoggerNet 3.4.1 or lower, the user needs to
download the most recent version of the operating system (OS)
for the datalogger. This installation installs the required
CRBasic files on the user’s computer so that the AVW200
instruction shows up in the editor.
NOTE
The AVW200 instruction is used to read measurements from one or more
vibrating wire sensors when the sensors are connected to the AVW200
channels directly or connected to a multiplexer that’s attached to the AVW200.
In addition to frequency, diagnostic information is returned for the sensor (see
the Dest parameter).
The datalogger program can run the AVW200 instruction in either the pipeline
mode (Section 6.1.1) or sequential mode (Section 6.1.2). In the pipeline mode,
the first execution of the instruction sets up the AVW200; subsequent
execution intervals retrieve the data values. If different beginning and ending
frequencies are required to measure different types of sensors, use multiple
AVW200 instructions with different beginning and ending frequencies
specified in each instruction. The sequential mode performs each instruction in
sequence; waits for each instruction completion; and then repeats this process
for each execution interval. The minimum scan rate for an AVW200 program
is 2 seconds per sensor.
Syntax
AVW200 (Result, ComPort, NeighborAddr, PakBusAddr, Dest, AVWChan,
MuxChan, Reps, BeginFreq, EndFreq, ExVolt, Therm50_60Hz, Multiplier,
Offset, [Optional] AmpThreshold)
Result
The Result parameter is a variable that indicates the success
or failure of the datalogger's communication attempt with
37
Summary of Contents for AVW200 series
Page 2: ......
Page 78: ...Appendix C Antennas Antenna Cables and Surge Protectors for the AVW206 AVW211 and AVW216 C 8...
Page 86: ...Appendix E Status Table E 4...
Page 104: ...Appendix H Additional Programming Examples H 12...
Page 110: ...Appendix I Using MD485 Multidrop Modems with AVW200 Interfaces I 6...
Page 111: ......