AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules
FIGURE 5.2.1-1. Deployment Communications Editor in DevConfig
Certain AVW206 settings must match the RF401 settings for
communications between the interface and radio to be
successful.
NOTE
Description of the Communication Settings follows:
Protocol
—choose "PakBus" for the “Protocol” setting. Please note that the
“Protocol” setting for the RF401-series radio must be set to either “PakBus
Aware” or “PakBus Node” for communications to be successful.
PakBus Address
—enter a PakBus Address that matches the PakBus address
specified in the CRBasic program that will control the AVW200. Each device
in a PakBus network must have a unique address. Valid settings are 1 - 4094.
RS-232 Baud Rate
—enter the baud rate in which you want to communicate.
Hop Sequence
—enter the radio ”Hop Sequence” that matches all of the RF401
radios and other AVW206 Interfaces in the network. Valid entries are 0-6.
27