5

 

Appendix A: Acronyms, Abbreviations 
& Definitions 

 

Term 

Meaning 

Adapter Plate (AP) 

An aluminum plate that mounts to the base station to display crosswalk 
signs.  

Base Station (BS) 

Fully integrated APS station that contains the microcontroller, push 
button, speaker, adapter plate (BS) 

COM Port 

Windows Serial communication port 

Extended Press 

On APS, holding the pedestrian push button down from 1-3 seconds may 
activate special features, including audible beaconing and extended 
pedestrian clearance interval. (EP) 

Intersection 
Worksheet 

Intersection Map of street names and station locations provided with 
installation packet. Pedestrian Stations are  identified with Campbell 
Company Work order # and Station Identification number 

Signal Power 
Interface (SPI) 

Power Source that interfaces with Pedestrian Signal Head power for 
Base Station Interface. 

Station ID # 

Identification number of base station for location and custom messaging 

Terminal Plug 

Electrical connection at the back of Base Station for Cabinet field wires  

USB Port 

USB docking plug on Base Station 

Utility 

Application to interface with Base Station 

.wav file 

A file format for storing digital audio data on a computer system 

 

 

Summary of Contents for AGPS Base Station

Page 1: ...stallation Manual 906 0003 Revision D January 20 2014 This Installation Guide provides guidance to those involved in the installation of the application This guide assumes that you have some knowledge...

Page 2: ...onic mechanical photocopying recording or otherwise without prior written permission from Campbell Company All copyright confidential information patents design rights and all other intellectual prope...

Page 3: ...ll rights reserved Page 3 of 15 Installation Guide 906 0003 Document Revision History Revision Revision Update Revised By Date A Released tbrennan 6 18 2012 B Released tbrennan 10 01 2012 C CAL TRANs...

Page 4: ...5 1 2 IDENTIFICATION 5 1 3 REFERENCE INFORMATION 5 1 4 POINTS OF CONTACT 5 2 Installation Plan 6 2 1 SCOPE 6 2 2 STANDARD COMPONENTS 6 2 3 TASKS 7 2 4 INSTALL UTILITY APPLICATION 7 2 5 INSTALLATION P...

Page 5: ...tion Advisor Guide Pedestrian System AGPS Base Station Fully Integrated Pedestrian Station FIPS Signal Power Interface SPI Utility Version 1 3 X Firmware Version 1 3 X 1 3 Reference information See AG...

Page 6: ...packet Pedestrian Stations are identified with the Campbell Company Work Order number and Station Identification number 2 3 Standard Components 1ea Base Station with four conductor cable 1ea Signal P...

Page 7: ...Base Station 6 Install SPI in Pedestrian Signal Head 7 Make Connections for the SPI 8 Test and Adjust 9 Fax checklist to Campbell Company 2 5 Install Utility Application The AGPS Utility application...

Page 8: ...ompany Technical Support if a security bit is needed for tactile arrow modification Note THE PEDESTRIAN RELIES ON THIS INFORMATION TO CROSS SAFELY Rubber mounting bumpers screw on to the back plate of...

Page 9: ...ion See Table 1 page 10 4 Place a small bead of silicone around the flange for the back plate and tighten screws 5 Use an anti seize compound on all screws 6 Place the pedestrian station on the pole a...

Page 10: ...left or right requiring two security screws and a security driver Campbell Company provides this hardware packet only when specified at the time of purchase Contact Campbell Company Technical Support...

Page 11: ...120 VAC wires sag below the housing and attach to the three position barrier terminal tighten firmly securing the SPI to the back of the housing See Table 2 Note The sag in the 120 VAC wire creates a...

Page 12: ...to the three position barrier terminal for the pedestrian signal head visual display See fig 1 7 a Orange to Don t Walk b White to Neutral c Blue to Walk Warning Danger All SPI leads become hot when...

Page 13: ...alk Phase message verify an audible locator tone is present at the clearance phase Flashing Don t Walk 6 Recheck all units for a full cycle to ensure all options and features operate as desired 7 Depe...

Page 14: ...l this application USB Configuration Utility A computer based USB configuration utility down load onto a portable computer A USB connection is required for base station communications 4 2 Hardware Req...

Page 15: ...om 1 3 seconds may activate special features including audible beaconing and extended pedestrian clearance interval EP Intersection Worksheet Intersection Map of street names and station locations pro...

Reviews: