Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
26
13.
IO-Link
This chapter describes the implementation of the SDCI (single-drop digital communication
interface) protocol, more commonly known as IO-Link, for the Camozzi proportional pressure
regulator.
Port type
Class A
Protocol version
V1.1
Device ID
1
Vendor ID
805
ISDU
Supported
Block parameter
Data Storage
SIO
Not supported
Local Parametrization
Bit rate
COM2 (38.4 kbps)
Minimum cycle time
2400 µs
Process data IN (PRE → Master)
2 byte
Process data OUT (Master → PRE)
2 byte
In according to the standard protocol, three different data exchange device-master type are
supported:
-
Process data: cyclic data exchange.
-
On-request data: on request data exchange, usually configuration parameter.
-
Events: events generated by the device, usually diagnostic parameters.
13.1.
Cyclic data
In case of the Regulator, there are two types of Process Data:
•
Target Pressure: input data with a size of 2 bytes is sent by the master and indicates the
output pressure of the regulator.
•
Read Pressure: output data with a size of 2 bytes is sent by the Regulator and indicates
the pressure read by its internal sensor.
The Pressure Regulator supports three units of measurement: psi/10, mbar and kPa.
The pressure target resolution based on the units is:
•
0,1 psi/bit
•
1 mbar/bit
•
1 kPa/bit
Diagnostic
Green
Regulator is working with no errors or
warnings
.
Red
The regulator has registered an
ERROR
. Pressure
regulation is
INTERRUPTED
.
Yellow/Orange
The regulator has registered a
WARNING
.
Pressure
regulation is
not interrupted
.
Wireless
Blu fixed
Wireless board is available and the regulator is
connected to the supervisor software UVIX
Blu blinking 1Hz
Wireless board is available but the regulator is not
connected to the supervisor software UVIX
Off
Wireless board is not available
LED
STATUS
MEANING
Diagnostic
Green
Regulator is working with no errors or
warnings
.
Red
The regulator has registered an
ERROR
. Pressure
regulation is
INTERRUPTED
.
Yellow/Orange
The regulator has registered a
WARNING
.
Pressure
regulation is
not interrupted
.
Wireless
Blu fixed
Wireless board is available and the regulator is
connected to the supervisor software UVIX
Blu blinking 1Hz
Wireless board is available but the regulator is not
connected to the supervisor software UVIX
Off
Wireless board is not available