Installation  and  Maintenance  Rules  for:

PFG-LP  -  PFG-LP-C

STANDARD  FEATURES

DESCRIPTION

OPERATION

-

-
-
-
-

-

-

Use  contact  capacity:

Fig.1

Operating  temperature:

Parts  in  contact  with  the  products  are  made  of  stainless  steel.

PFG-LP

PFG-LP  float  level  gauges  for  liquids

Die-cast  aluminium  casing  UNI 5076.  IP65  protection.

PFG-LP-C

Maximum  working  pressure:

PFG-LP

  is  a  float  level  gauge  used  to  detected  the  level  of  liquids  in  tanks.

Its  operates  by  means  of  a  float  centered  to  the  fixed  support  on  the  flange  of  the  gauge.  The  float  moves  as  the  level
of  the  liquid  increases  and  this  movement  is  transmitted  to  a  microswitch  housed  in  the  body  of  the  gauge,  causing
its  electric  contact  to  change  status.
The  instrument  consist  of  a  die-cast  aluminium  casing  housing  a  precision  microswitch  and  a  rocker  device  controlled
by   magnetic   induction   that   activates   the   microswitch.   This   casing   is   enbloc   with   the   flange   that   fixes   the   instrument
which  in  turn  supports  the  float  that  tests  the  liquid.
The   centering   articulation   of   the   float   is   protected   by   an   elastic   casing   in

When  it  is  not  operating,  the  float  assumes  a  negatively  slanting  position  of
about  10°  in  relation  to  its  horizontal  axis.
As   the   level   of   the   liquid   rises,   the   float   is   influenced   by   the   movement
and   shifts   from   its   initial   position   until   it   slants   positively   by   about   10°   in
relation  to  its  horizontal  axis  ( Fig.1 ).
This  movement  is  transmitted  by  magnetic  induction  by  the  magnet  fixed  to
the  float,  to  the  rocker  device  in  the  body  of  the  instrument  which  activates
the  microswitch.
There   is   no   more   or   less   protected   passage   between   the   liquid   in   the
tank   and   the   interior   part   of   the   level   gauge   since   magnetic   induction   is
transmitted  to  a  lowered  part  of  the  stainless  steel  flange,  thus  guaranteing
100%  impermeability.  The  microswitch  is  a  switch  contact  type.

00956  19.10  -  Rev. 00

SAFETY  RULES

articulation  itself,  since  this  could  hamper  its  movement.
All  parts  in  contact  with  the  liquid  ( flange,  articulation  and  float )  are  made
of  stainless  steel  to  prevent  problems  if  the  treated  liquid  is  aggressive.

Neoprene   which   prevents   sticky   substances   from   accumulating   within   the

All  the  appropriate  safety  precautions  must  be  taken  when  electrically  operated  equipment  is  used,  in  order  to  reduce
the  risk  of  fire  outbreaks,  electric  shock  and  injuries  to  persons.

- Keep  the  work  zone  clean  and  orderly.  Accidents  are  more  likely  to  occur  in  untidy  areas  and  environments.
- Before  beginning  work,  make  sure  that  the  level  gauge  is  in  a  perfect  condition.  Damaged  or  broken  parts  must  be

repaired  or  replaced  by  competent  personnel  authorized  by  the  Manufacturer.

- All   verifications,   inspections,   cleaning   and   maintenance   operations,   part   changes   and   replacement   must   be   carried

out  with  the  level  gauge  disconnected.

- It  is  absolutely  forbidden  for  children,  unauthorized  and/or  inexpert  persons  to  touch  or  use  the  level  gauge.
- Make  sure  that  the  earthing  is  efficiently  connected  when  the  instrument  is  installed.
- Periodically  check  to  be  sure  that  the  cable  is  in  a  perfect  condition  and  replace  it  if  is  damaged.  This  operation  must

only  be  carried  out  by  competent  and  authorized  persons.  Only  use  extension  cables  of  the  permitted  type  and  marked.

- Protect  the  cable  against  high  temperatures,  lubricants  and  sharp  edges.  Do  not  twist  or  knot  the  cable.
- Do  not  allow  children  or  unauthorized  persons  to  touch  the  cable.

The  float  level  gauge  

PFG-LP

  is  made  in  compliance  with  the  regulations  in

force  in  the  European  Union  and  specifically  with:

INSTALLATION

The  gauge  is  mounted  on  the  external  wall  of  the  tank  by  means  of  a  counterflange  sized  as  shown  in  the  drawing
( see  REFERENCE  FIGURES ).
The  horizontal  axis  of  the  float  must  be  perpendicular  to  the  tank  wall,  thus  parallel  to  the  surface  of  the  still  liquid.
Equipped   with   a   float   with   a   curved   stem,   gauge  

PFG-LP-C

   can   be   mounted   on   tank   walls   slanting   45°   at   most,

since  the  curved  stem  achieves  optimum  operating  conditions  just  as  through  the  float  was  parallel  to  the  surface
of  the  liquid  ( Fig.2 ).

10 A  at  250 V.AC.
from  -20  to  +120 °C.
25 bar.

standard.
with  curved  float.

Serial Number: 00.112.0000

Via dell'Industria 12 - 42025  CAVRIAGO  RE - Italy

Production  Year  0000

FLOAT LEVEL GAUGE

II 2GD Ex d IIB T4 Ex tD A21 IP65 T135°C - 

TÜV 08 ATEX 362388 X

Ex d IIB T4 Gb - Ex tD A21 IIIC T135°C Db Ip65 - 

IECEx QAR TUN 08.0033

0948

PFG-LP

Ambient temperature range -10 to +100°C

Max. temperature inside storage bin 100°C

R

S.n.c. di Guazzetti Giovanni & C.

COSTRUZIONI  MECCANICHE  ELETTRICHE

Via dell'Industria 12 - 12/A - 42025 CAVRIAGO - RE - Italy

Tel.: 0522/942641 - 0522/941172

www.camlogic.it