background image

1

Passive 

DC signal isolator

SINEAX TI 816

TI 816-5 Be      996 118-01     09.05

Safety precautions to be strictly observed are marked with 
following symbols in the operating instructions:

Camille Bauer LTD
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 35 35
e-mail: [email protected]
http://www.camillebauer.com

Operating Instructions

3. Brief description

The signal isolator SINEAX TI 816 serves to electrically insulate 

an

 analogue DC 

signal in the range 0...20 mA which depending on version is then converted to 
a current or voltage signal (0...20 mA or 0...10 V). It does 

not

 require a separate 

power supply.
The instrument fulfils all the important requirements and regulations concerning 
electromagnetic compatibility 

EMC 

and 

Safety 

(IEC 1010 resp. EN 61 010). It was 

developed and is manufactured and tested in strict accordance with the 

quality 

assurance standard

 ISO 9001.

Contents

  1.  Read first and then …  ................................................................................... 1
  2.  Scope of supply ............................................................................................. 1
  3.  Brief description ............................................................................................. 1
  4.  Versions .......................................................................................................... 1
  5.  Technical data ................................................................................................ 1
  6.  Mounting ........................................................................................................ 1
  7.  Electrical connections .................................................................................... 2
  8.  Commissioning and maintenance .................................................................. 2
  9.  Releasing the signal isolator .......................................................................... 2
10.  Dimensional drawings .................................................................................... 2
11.  Declaration of conformity ............................................................................... 2

1. Read first and then …

The proper and safe operation of the device assumes that the 
operating instructions is 

read carefully

 and the safety warnings 

given in the various Sections

 

6. Mounting

 

7. Electrical connections

are 

observed

.

The  device  should  only  be  handled  by  appropriately  trained 
personnel who are familiar with it and authorised to work in 
electrical installations.

Unauthorized  repair  or  alteration  of  the  unit  invalidates  the 
warranty!

2. Scope of supply

Signal isolator

 (Fig. 1)

1 ea. operating instructions (Fig. 2) in English, French, German

Fig. 1

Fig. 2

1

 With current signal 

2

 With voltage signal

4. Versions

There are two versions of the DC signal isolator SINEAX TI 816 available.

Description

Output signal A

Order code

Order No.

Passive 

DC signal isolator

input signal E: 0…20 mA,
with 1 isolation and
transmission channel, in
carrying rail housing N12

0…20 mA

816-5110

990 722

0…10 V

816-5111

994 089

5. Technical data

Input signal E 

DC current: 

0…20 mA

Max. permissible current: 

50 mA

Voltage limiter: 

18 V ± 5% (with zener diode)

Voltage drop: 

< 2.1 V (for 500 

 burden)

Overshoot: 

< 20 µA (typical 5 µA)

Output signal A 

DC current 

or 

DC voltage: 

0…20 mA 

or 

0…10 V

Limit: 

Approx. 30 mA

1

 

Approx. 15 V

2

Max. burden: 

600 

1

Internal resistance: 

500 

2

Residual ripple: 

< 20 mV ss

Time constant: 

Approx. 5 ms

Accuracy data

Error limits: 

< ± 0,1%

1

 

(reference value 20 mA,

 

linearity error included)

 

< ± 0,2%

2

 

(reference value 10 V,

 

linearity error included)

Ambient conditions

Operating temperature:: 

–20 to + 65 °C

Storage temperature: 

–40 to + 85 °C

Annual mean
relative humidity: 

 75% Standard climatic rating

Seismic test: 

5 g, < 200 Hz, 2 h in each of 3 directions

Shock test: 

50 g,

 10 shocks in each of 3 directions

Altitude: 

2000 m max.

Indoor use statement

6. Mounting

The  SINEAX  TI  816  isolator  is  suitable  for  mounting  on  two  different  types  of 
standard rails: 
–  onto the G-type rail EN 50 035-G32 
  or 
–  onto the top-hat rail EN 50 022-35

×

7.5.

The instruments must only be disposed of in the 
correct way!

Reviews: