EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
37/63
Install & Operating Manual
CleanSeal V3
Connecting the MIP Drive Shaft
Connecting to the Housing Drive Port
•
Insert the shaft end into the housing interface.
Note the drive pin is asymmetrical !
Place shorter side to match the setting screw
position in the interface hub.
•
Fasten with 2 supplied screws.
Connecting to the ControlBox Drive Port
•
For best dust- and airtightness, place fiber
washer
before inserting the shaft end
into the box.
•
Fasten with nut
.
24
M20
2
M3