EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
20/63
Install & Operating Manual
CleanSeal V3
8.4
Compression Mounting
Standard Compression
The standard CleanSeal support system allows housing installation by both compression and
suspension for most practical situations.
•
Recommended cutouts (
see § 8.2
) will allow to insert any standard housing straight into the cutout,
no balancing required
•
General purpose stainless steel support brackets are included as accessories with every housing
PLEASE NOTE:
Co
mpression mounting requires “
Option B
”
- Pressure Screw Kit for 1 housing (4x)
to be ordered separately:
Ref. 1068200
Bracket positioning
for
panel thickness
Orientation
min
ca. 30 mm
max
< 65 mm
Orientation
min
> 65 mm
max
ca. 105 mm
(
…
120 mm *)
h
Bracket
s
4x
if pressure screw is assembled on the
inserted housing with brackets in place !
13
M8
A* / B* +
PLEASE NOTE:
For the maximum necessary
integration space in
compression mounting,
including enlarged pressure
plates of Option B,
please add
+88 mm (2x19 + 2x25mm)
To the “footprint” values
from § 8.3.1