Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9827
2663
SD17: Holding: Differential Pressure Instantaneous
Reading
FP
"H2O@68°F
RO
9829
2665
SD17: Holding: RTD Instantaneous Reading
FP
°F
RO
9831
2667
SD17: Holding: Analog Input 1 Instantaneous
Reading
FP
V
RO
9833
2669
SD17: Holding: Analog Input 2 Instantaneous
Reading
FP
V
RO
Slave 18 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9851
267B
SD18: Holding: Update Date
FP
MMDDYY
RO
9853
267D
SD18: Holding: Update Time
FP
HHMMSS
RO
9855
267F
SD18: Holding: Flow Run Volume Daily Total
FP
MCF
RO
9857
2681
SD18: Holding: Flow Run Volume Flow Rate
FP
MCF/day
RO
9859
2683
SD18: Holding: Flow Run Mass Daily Total
FP
lbm
RO
9861
2685
SD18: Holding: Flow Run Mass Flow Rate
FP
lbm/day
RO
9863
2687
SD18: Holding: Flow Run Energy Daily Total
FP
Btu
RO
9865
2689
SD18: Holding: Flow Run Energy Flow Rate
FP
Btu/day
RO
9867
268B
SD18: Holding: T1 Volume Daily Total
FP
bbl
RO
9869
268D
SD18: Holding: T1 Volume Flow Rate
FP
bbl/day
RO
9871
268F
SD18: Holding: T2 Volume Daily Total
FP
bbl
RO
9873
2691
SD18: Holding: T2 Volume Flow Rate
FP
bbl/day
RO
9875
2693
SD18: Holding: Static Pressure Instantaneous
Reading
FP
psig
RO
9877
2695
SD18: Holding: Differential Pressure Instantaneous
Reading
FP
"H2O@68°F
RO
9879
2697
SD18: Holding: RTD Instantaneous Reading
FP
°F
RO
9881
2699
SD18: Holding: Analog Input 1 Instantaneous
Reading
FP
V
RO
9883
269B
SD18: Holding: Analog Input 2 Instantaneous
Reading
FP
V
RO
Slave 19 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9901
26AD
SD19: Holding: Update Date
FP
MMDDYY
RO
9903
26AF
SD19: Holding: Update Time
FP
HHMMSS
RO
9905
26B1
SD19: Holding: Flow Run Volume Daily Total
FP
MCF
RO
9907
26B3
SD19: Holding: Flow Run Volume Flow Rate
FP
MCF/day
RO
9909
26B5
SD19: Holding: Flow Run Mass Daily Total
FP
lbm
RO
9911
26B7
SD19: Holding: Flow Run Mass Flow Rate
FP
lbm/day
RO
189
Scanner 3100 Modbus Protocol
Section 2