E-7
Scanner
®
2000 microEFM
Appendix E
Table E.4—Transducer Error (XD_Error) and Block Alarm Codes
Value
Error
Description
16
Unspecified error
Indicates occurrence of unidentified error
17
General error
Error cannot be classified as one of the following errors
18
Calibration error
Error occurred during calibration of the device or calibration error
detected during device operation
19
Configuration error
Error occurred during configuration of the device or configuration
error detected during device operation
20
Electronics failure
Electronic component has failed
21
Mechanical failure
Mechanical component has failed
22
I/O failure
I/O failure has occurred
23
Data integrity error
Data stored within the system may no longer be valid due to non-
volatile memory checksum failure, data verify after write failure,
etc.
24
Software error
Software has detected an error. Possible causes: improper
interrupt service routine, arithmetic overflow, watchdog timer, etc.
25
Algorithm error
Algorithm used in the transducer block produced an error.
Possible causes: overflow, data reasonableness failure, etc.
Control Registers
The Control Registers allow specific functions to be implemented via the communications port.
Table E.5
shows the value to be written to the control register to implement the desired function.
Table E.5—Control Registers
Code
Function
20000
Transfers the polling totals and averages and polling run times to the previous polling totals,
averages and previous run-time registers, increments the polling index register, and resets
the polling totals, averages and polling run-time registers.
30000
Clears all flow totals
30001
Clears Flow Run 1 totals
30003
Clears Turbine 1 totals
30004
Clear Turbine 2 totals
30050
Clears all pulse output latches
30051
Clears a Pulse Output 1 latch
30061
Adds pulses specified in Control Register 2 to Pulse Output 1 Accumulator
30100
Clear all Alarm States
30101
Clear Flow Run Alarm Status
30102
Clear Input Alarm Status
40000
Loads factory defaults
40040
Resets the microcontroller (watchdog)
50050
Creates a partial archive record (daily and interval)
Summary of Contents for Scanner 2000 microEFM
Page 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Page 26: ...26 Section 1 Scanner 2000 microEFM ...
Page 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Page 106: ...B 2 Appendix B Scanner 2000 microEFM ...