D-34
Appendix D
Scanner
®
2000 microEFM
Flow Calculation Parameter Registers (1-16)
The Flow Calculation Parameter Registers definition is dependent upon the flow rate calculation method
that is implemented. The following table describes the function of each of these registers for each of the
supported calculation methods.
Reg.
Num
AGA-3
ISO-5167
Cone –Spool
Cone -Wafer
AGA-7
1
Pipe Size (Corrected)
Pipe Size (Corrected)
Pipe Size (Corrected)
Pipe Size (Corrected)
2
Plate Size (Corrected) Plate Size (Corrected) Plate Size (Corrected) Temperature Ratio
3
Beta (Corrected)
Beta (Corrected)
Beta (Corrected)
Pressure Ratio
4
Plate Size
(configured)
Plate Size
(configured)
Plate Size
(configured)
Supercompressibilty
5
Stability Index
Stability Index
Stability Index
<Reserved>
6
Y
Y
Y
<Reserved>
7
Cd
Cd
Cd
<Reserved>
8
Ev
Ev
Ev
<Reserved>
9
Flow Extension
(sqrt["H20*lbm/cf3])
Flow Extension
(sqrt[pa*kg/m3])
Flow Extension
(sqrt[pa*kg/m3])
<Reserved>
10
Flowing Density
(kg/m3)
Flowing Density
(kg/m3)
Flowing Density
(kg/m3)
Flowing Density
(kg/m3)
11
Quality (Vapor Liquid
Fraction)
Quality (Vapor Liquid
Fraction)
Quality (Vapor Liquid
Fraction)
<Reserved>
12
Liquid Heating Value
Liquid Heating Value
Liquid Heating Value
<Reserved>
13
Liquid Flowing
Density
Liquid Flowing
Density
Liquid Flowing
Density
<Reserved>
14
Estimated Liquid
Mass Flow Rate
Estimated Liquid
Mass Flow Rate
Estimated Liquid
Mass Flow Rate
<Reserved>
15
Apparent Mass Flow
Rate
Apparent Mass Flow
Rate
Apparent Mass Flow
Rate
Apparent Mass Flow
Rate
16
Lockhart-Martinelli
Lockhart-Martinelli
Lockhart-Martinelli
<Reserved>
Base Units/Configured Units
The holding registers allow users to read data in terms of
configured
units of measurement and
base
units. The
configured units follow the settings based on the Unit setting register and the unit scale and offset registers.
The base units will always have the same unit of measurement independent of the unit, scale and offset
settings. Also note that the log data is always in terms of base units. It is recommended to configure the units
of measurement using the software.
Polling Registers
The Scanner 2000 stores volumes, averaged values, and flow times since the last polling sequence in a set of
polling registers. Additionally, the instrument stores the number of polls requested in the polling index.
The polling sequence is started by writing a value of 20,000 to the Control Register. This transfers the polling
totals, averages, and run times to the previous polling registers, increments the polling index and resets the
polling totals, averages and run-time registers. Note that the polling registers are displayed in base units and
configured units.