41
MC-III™ EXP Flow Analyzer
Section 4
Section 4—Configuration and Operation via Software
The MC-III™ interface software provides easy access to all configuration parameters and is the quickest
way to configure the device. While basic parameters can be configured with the keypad (see Section 3), the
interface software is the only means of accessing every configurable parameter. For example, multipoint
calibration for liquid or gas measurement and gas volume correction parameters for measuring gas in standard
cubic feet are configurable only with the interface software.
, provides a quick reference for configuration methods.
Installing the Software
The MC-III interface software is stored on a CD that is shipped with each instrument, and it installs directly
onto a PC or laptop. To install the interface software on a computer, perform the following steps:
1.
Place the MC-III CD in your CD-ROM drive. The MC-III install screen will load automatically.
2.
Click “Install MC-III” on the introductory screen.
3.
Click on “Next” to initiate the installation, and follow the instructions on the screen. An MC-III icon
(Figure 4.1) will appear on the desktop of the user’s PC or laptop when installation is complete.
To access the interface software, click on the MC-III icon on your desktop or go the Start menu and select
Programs>NuFlo>MC-III 2.1.0>MC-III 2.1.0.
Figure 4.1—MC-III desktop icon
User Documentation
Click the Help menu in the task bar at the top of the Welcome screen (
) to access
documentation for installing, configuring, and operating the MC-III EXP flow analyzer. This documentation
includes:
•
a “read me” file for general reference (includes contact information for technical assistance)
• an electronic copy of the user manual
•
an electronic copy of the quick-start guide for installing and configuring the MC-III EXP
• a COM troubleshooting guide for addressing communications errors (this guide will automatically display
on screen when a communication error is detected)
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......