Entering a Calibration Factor
When the volume is to be expressed in barrels (BBL), gallons (GAL), liters (LIT), cubic meters (M
3
), or cubic
feet (CF), and the flow rate is to be expressed in barrels, gallons, liters, cubic meters or cubic feet per day, per
hour, per minute, or per second, the MC-III EXP calculates the divisor automatically; only the turbine meter
calibration factor is required.
When the volume is to be expressed in a unit other than the preprogrammed units listed above, a calculated
divisor must be entered at the K-Factor prompt. See
Entering a Calculated Divisor, page 32
.
To Enter a Calibration Factor:
Enter the K-Factor menu.
Press K-FACTOR MENU.
K-FACTOR
MENU
00000000
M
3
BBL
GAL
LIT
CF
CF
X1000
X1000
Select the unit of measure associated
with the calibration factor (typically,
pulses per gallon).
Press UP ARROW until the correct
unit is displayed.
TEST
Enter the decimal point position for
the calibration factor.
Press LEFT ARROW to select the
decimal point.
LOG
00000000
M
3
BBL
GAL
LIT
CF
CF
X1000
X1000
.
Press UP ARROW to change the
position of the decimal point.
TEST
Press LEFT ARROW to save the
decimal point position and proceed
with entering a calibration factor.
LOG
Enter the calibration factor, starting
with the last digit and entering digits
right to left.
Press UP ARROW until the last digit
of the calibration factor is displayed.
TEST
00000000
M
3
BBL
GAL
LIT
CF
CF
X1000
X1000
Press LEFT ARROW to select the
next digit to the left.
Repeat using UP and LEFT arrows to
enter all remaining digits.
LOG
Press ENTER.
SAVE
ENTER
The Input Sensitivity menu will appear following the entry of the calibration factor. See
, for the input sensitivity configuration procedure.
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......