Flat Field Selector (VC-12MC/VC-25MC/VC-25MC2 Only)
As mentioned above, the active Flat Field data is stored in the camera
’s volatile memory and the data is lost if
the camera is reset of powered off. To use the active or generated Flat Field data after the camera is powered on
or reset, you need to save them in the camera
’s non-volatile memory. The VC-12MC, VC-25MC and VC-25MC2
models provide four reserved areas in the camera
’s non-volatile memory available for saving Flat Field data. You
can use the
Flat Field Selector
feature to select one of the four reserved areas.
Figure 8.16 Flat Field Selector
Saving a Flat Field data
To save the current active Flat Field data into a reserved area in the camera
’s flash memory,
1.
Use the
“sfs 0/1/2/3” command to specify a reserved area where the current active Flat Field data will be
stored.
2.
Use the
“sfd” command or click the
Save to Flash
button in Configurator to save the active Flat Field data
to the selected reserved area.
Loading the Flat Field data
If you saved a Flat Field data into the camera
’s non-volatile memory, you can load the saved Flat Field data from
the camera
’s non-volatile memory into the camera’s active Flat Field data.
1.
Use the
“sfs 0/1/2/3” command to specify a reserved area whose Flat Field data will be loaded into the
camera
’s active Flat Field data.
2.
Use the
“lfd” command or click the
Load from Flash
button to load the selected Flat Field data into the
active Flat Field data.