background image

Video intercoms for the IP360 system

XTS 7IP WH WIFI

XTS 7IP BK WIFI

XTS 7IP WH WFBF

INSTALLATION AND SETTINGS MANUAL

EN English

FB01185-EN

Summary of Contents for XTS 7IP BK WIFI

Page 1: ...Video intercoms for the IP360 system XTS 7IP WH WIFI XTS 7IP BK WIFI XTS 7IP WH WFBF INSTALLATION AND SETTINGS MANUAL EN English FB01185 EN ...

Page 2: ...artphones and tablet PCs by using the corresponding apps For the system to be remotely controlled the device must be connected to a home WiFi network with internet access This type of system functions properly when the device receives a high quality WiFi signal there is a permanent connection established by your contract with the internet service provider The connection must support the data flow ...

Page 3: ...ng Function of terminals Local power supply input Landing call input Alarm input Technical data Type XTS 7IP WIFI local power supply V DC 14 to 18 PoE power supply IEEE 802 3af PD Maximum draw mA 420 Consumption in stand by mode mA 340 Stocking temperature C 25 to 70 Operating temperature C 0 to 40 Protection rating IP 30 Video codec H 264 Capacitative TFT Touch screen Display pixels 1024 x 600 Wi...

Page 4: ...m 1 83 5 mm 3 2 4 H 155 165 cm H 125 135 cm p 4 Manual FB01185 EN 06 2018 CAME S p A The contents of this manual may be changed at any time and without notice This is a translation of the original instructions INSTALLING ...

Page 5: ...iFi network Install the indoor receiver away from any metal objects that may interfere with the signal or from any devices that generate magnetic fields Install it in the same room as the router or have the least possible number of walls separating the router and the indoor receiver If the place chosen for installing the indoor receiver is not easily reached by a sufficiently intense WiFi signal w...

Page 6: ...The contents of this manual may be changed at any time and without notice This is a translation of the original instructions Examples of installation The devices Master Slave setting is programmed via the PCS XIP software Single household system with PoE power supply Single household system with local power supply and WiFi connected indoor receiver ...

Page 7: ...R Wi Fi SWITCH PoE SWITCH PoE MODEM ROUTER Wi Fi MODEM ROUTER Wi Fi MODEM ROUTER Wi Fi Master Slave p 7 Manual FB01185 EN 06 2018 CAME S p A The contents of this manual may be changed at any time and without notice This is a translation of the original instructions Multi household system with indoor receiver for apartments ...

Page 8: ...e managed by the Master indoor receiver in one apartment whether they are connected to the LAN line or reachable via the WiFi network or the mobile phone network via the CAME Connect service When there s an incoming call all the devices programmed to answer will ring The caller s image preview may be viewed on five devices at most One of these is the Master indoor receiver The high resolution imag...

Page 9: ...line or reachable via the WiFi network or the mobile phone network via the CAME Connect service When there is an incoming call all the devices programmed to answer will ring The caller s image preview can be viewed by up to five devices one of which will always be the master indoor receiver The high resolution image can be viewed on the master indoor re ceiver and on at most four other indoor rece...

Page 10: ...l instructions Household in which several indoor receivers are connected to the local network on which the local ETI MiniSER server acts as master for the apartment An incoming call from the entry panel can have up to 10 devices ring whether they are connected to the LAN line or reachable over the WiFi network or the mobile network via CAME Connect When there s an incoming call all the devices pro...

Page 11: ...nced settings Tones Display Home Back Info 19 02Thursday 01 Feb 2018 Settings Messages CCTV Home Back Info 19 02Thursday 01 Feb 2018 COMMISSIONING Once the wiring is complete the functions essential for the device to work properly need to be programmed Scroll the available pages Select item A Scroll the list Select menu item B This section requires specific know how in operating the vid eo interco...

Page 12: ...f there are no special needs this mode lets you continue with the settings without adding any additional data Static The device s IP address is manually assigned E IF you have chosen a static IP address enter the device s IP which must belong to the same subnet as that of the router and of the other connected devices F If the netmask is different from the default one provide the proper netmask G P...

Page 13: ...ion Configuring the Wireless connection Top save the setting touch button K To establish connection to a WiFi network with a hidden SSID touch button J On the page provided yo can enter an SSID that is network name type of security encryption and password when required To connect touch this button L Top save the setting touch button K H This button is for enabling the WiFi network This icon indica...

Page 14: ... 19 02Thursday 01 Feb 2018 A Device s univocal code B For enabling or disabling the VoIP remote control of the video in tercom call The factory settings require that the CAME Connect connection is disabled The CAME Connect connec tion must be active to receive calls on the App CAME Connect only on the master indoor receiver C URL of the service for remote calls the default one is xip01 cameconnect...

Page 15: ...g the SAVE button a guided procedure is launched which lets you choose the server or master device to which to connect your device One you have entered the Flat ID call code assigned to your indoor receiver through the PCS Xip during programming the procedure is complete Manual Automatic Home Back Info 19 02Thursday 01 Feb 2018 Save None Generic XIP server Manual Mode A In this space enter the SIP...

Page 16: ...hursday 01 Feb 2018 Automatic door opener This function which is especially useful for businesses lets you automatically open the entrance once the call but ton is pressed on the entry panel The activation of this function can be programmed to schedule time slots and days of the week A Touch the button to add a new time slot B Touch the empty sections and in the pop up window set the start and fin...

Page 17: ...ed Thu Fri Mon Tue Wed Thu Fri 08 30 12 30 Home Back Info 19 02Thursday 01 Feb 2018 For editing the selected ele ment For eliminating the selected element Touch the button Back to return to the list of configurable parameters C From the drop down menu choose the total number of frames that you want on the main page Each page has six frames at most the last one is always the settings section User i...

Page 18: ... via the PCS Xip software to match their systems structure C Touch the button to set the indoor receiver to slave mode This setting is only available on the master indoor receivers The changed mode requires the device to be reconfigured D Touch the button to return all the local settings to the default factory settings administrator password required the default password is 112233 A Touch the butt...

Page 19: ...ressed in seconds In the Chrome Firefox Safari browsers address bar type the de vices address Select the INSTALLER access option and type the default 112233 password to access the settings screen views Accessing by using the User credentials for which the default password is 123456 only lets you browse the following pages as well as any user dedicated pages There is no scroll bar on the right on t...

Page 20: ...gnostics System Date and Time Network SIP Credentials IP video cameras Voicemail Maintenance Diagnostics Maintenance Update This window is for upgrading the device s firmware as follows A Press the button select the file with the firmware upgrade within your computer and launch the pro cess Node state On master indoor receivers this window is for viewing the state of the connection on SIP nodes B ...

Page 21: ... Maintenance Diagnostics D This is for choosing where to save the LOG files among Local RAM the file is saved in the device s temporary memory Local FLASH the file is saved in the device s internal memory Warning The storage capacity is limited Remote the file is saved onto a remote server for which you need to enter the IP address E Launch log file recovery Diagnostics A This section brings toget...

Page 22: ...p 22 Manual FB01185 EN 06 2018 CAME S p A The contents of this manual may be changed at any time and without notice This is a translation of the original instructions ...

Page 23: ...p 23 Manual FB01185 EN 06 2018 CAME S p A The contents of this manual may be changed at any time and without notice This is a translation of the original instructions ...

Page 24: ... this manual conform to Directive 2014 53 EU The complete wording of the EU declaration of conformity is available at the following Internet address www came com Decommissioning and disposal Dispose of the packaging and the device at the end of its life cycle responsibly in compliance with the laws in force in the country where the product is used The recyclable components are marked with a symbol...