Menu map

F 1  

Total stop function (1-2)

F 2 

Function associated to input 2-CX

F 3 

Function associated to input 2-CY

F 19 

Automatic closing time

F 21 

Pre-flashing time

F 28 

Adjusting opening speed 

F 29 

Adjusting the closing speed

F 30 

Adjusting the slow-down speed when opening

F 31 

Adjusting closing-slow-down speed

F 33 

Adjusting calibration speed

F 34 

Sensitivity during movement

F 35 

Sensitivity during slow down

F 37 

Adjusting the beginning slow-down point of the motor when opening

F 38 

Adjusting the beginning slow-down point of the motor when closing

F 39 

Adjusting the beginning opening strike point of the motor 

F 40 

Adjusting the beginning closing strike point of the motor 

F 49 

Combo connection  functions

F 50 

Saving data in the memory roll

F 51 

Reading memory roll data

F 52 

Passing parameters from MASTER TO SLAVE

F 53 

Anti-Pass-Back function

F 54 

Direction choice function associated to the Anti-pass-back function

F 55 

Alarm activation function

F 56 

Setting the number of the peripheral

F 57 

Limit-switch closing offset functions

U 1 

Adding a new user

U 2 

Cancelling one user

U 3 

Completely cancel users

A 1 

Leaf type

A 2 

Motor testand

A 3 

Calibrating travel

A 4 

Reset parameters

H 1 

Software version

A 2 (Motor test): 

activate the test to check whether the turnstile works properly (see the paragraph about 

motor test

).

0

 = Deactivated; 

= Activated.

Confirm with the ENTER button after choosing the value for each feature.

Motor test and calibration menu

A 1 (Wing barrier type) :

 defining the wing barrier.

Note: the choice of wing-barrier type limits some parameters in terms of speed, end strikes, and the such. This 
ensures the proper functioning of the operator.

= glass leaf (default);

  

2

= Plexiglas leaf.

Important! We suggest starting the programming by first doing the following: 
1 Defining the wing-barrier type;
2 Motor test;
3 Calibration of travel.

Summary of Contents for Wing 40

Page 1: ...Installation manual WING40 SWING TURNSTILE English EN 119G3565EN...

Page 2: ...data must be clearly visible Before connecting the turnstile to the power supply make sure the identi cation data corresponds to the mains data The turnstile must be connected to an effective complian...

Page 3: ...r Plexiglas or tempered glass wing barrier The wing barrier opening in either direction can be activated by a card reader photocells or other command device The 90 wing barrier opening speed is pre se...

Page 4: ...data and information in this manual may be changed at any time and without prior warning 1 Outer lining tube 2 Wing barrier 3 Cover door lock 4 Top cap 5 Central column 6 Anchoring base 7 Electronic b...

Page 5: ...e continuity in the protective circuit are fitted with more insulation than other internal conductive parts Make sure the entrance way is in a proper state and level Section off the installation zone...

Page 6: ...0 09 2012 CAME Cancelli Automatici S p A The data and information in this manual may be changed at any time and without prior warning 1 Swing turnstile 2 Command device 3 Safety barrier 4 Junction box...

Page 7: ...late the centering pin and lock extender and separate them Slip the tube out of the cen tral column Preliminary operations Installation The following illustrations are just examples in that the space...

Page 8: ...are no dips on the ground where you will anchor the turnstile Position the anchoring base as shown in the drawing the gate wing is perpen dicular to the wall Use a pencil to mark anchoring holes Note...

Page 9: ...al column onto the base Before fastening the turnstile to the ground lay the cable inside the central column see drawing Note apply the ferrite to the command accessories cables Fasten column and base...

Page 10: ...t to check the position of the endstops If you wish to adjust the wing bar rier opening change the position of the mechanical endstops see illustrations shown below The default position of the endstop...

Page 11: ...m the buffer loosen the buffer tighten the screw and re tighten the buffer Rest the leaf against the buffer Position the limit switch so that the buffer is perfectly parallel and resting against the l...

Page 12: ...may be changed at any time and without prior warning Position the drive shaft as shown in drawing A Distribute the electrical cables inside the cable passing tube Insert the tube Reinsert the wing bar...

Page 13: ...n der above the plate position and fasten the hooking bracket above the extender see figure B Position the electronic control board s support above the support bracket only after passing the electric...

Page 14: ...rogramming indicator LED 3 Memory roll card connector 4 R700 board connector for the first command device 5 R700 board connector for the second command device 6 Display 7 Terminals for control devices...

Page 15: ...g the 24V AC acces sories Overall allowed power 10 W Power supply 24 V DC Clean N O contact connecting to a warning device Contact rated for 24 V 500 mA C NO2 contact warns that wing barrier is open C...

Page 16: ...ature F 54 is set on 2 the device commands the opening wing barrier on the side opposite that of contact 2 3 N B plug in the R700 coding card for the TSP00 sensor or the LT001 card reader to be recogn...

Page 17: ...warning Programming Memorising data Description of programming commands The ESC button is for exiting menus cancelling any changes Memory roll R700 card When using transponders or card readers fit the...

Page 18: ...ion functions F 50 Saving data in the memory roll F 51 Reading memory roll data F 52 Passing parameters from MASTER TO SLAVE F 53 Anti Pass Back function F 54 Direction choice function associated to t...

Page 19: ...C2 if unused set the feature to 0 0 Deactivated default 1 Activated F 2 2 CX input N C safety contact input reopen while closing 0 deactivated default 1 Activated F 3 2 CY input N C safety contact in...

Page 20: ...ault 1 1 second 2 2 seconds 5 5 seconds F 28 Opening travel speed setting the opening travel speed calculated as a percentage 40 40 of the motor speed minimum 100 100 of the motor speed maximum F 30 O...

Page 21: ...opening endstop The slow down starting point is calculated in degrees 10 10 45 45 F 38 Motor closing slow down point adjusts the motor s beginning point of slow down before the closing endstop The slo...

Page 22: ...ing barrier in the direction opposite that of contact 2 3 F 55 Alarm setting the alarm activation time It activates when contacts 2 CX and 2 CY are opened with wing barrier s closed or during the pre...

Page 23: ...1 Registering users entering 150 users max via the transponder card see paragraph about adding users 0 Deactivated 1 Activated U 2 Cancelling users cancelling single users see paragraph on cancelling...

Page 24: ...or a command Keep pressed the button indicated by the arrow and check that the wing barrier completes a clockwise movement Do the same procedure using the button indica ted by the arrow to check that...

Page 25: ...on of travel mode The wing barrier will move clockwise until it reaches the mechanical stop The wing barrier will invert the movement until it reaches the mechanical stop N B before calibrating the tr...

Page 26: ...ash for some seconds Send the code with the transponder card or other command device the number stays fixed for an instant to show that user registration is complete Select U 2 Press ENTER to confirm...

Page 27: ...89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141...

Page 28: ...ombined connection Specific connections Turnstile MASTER settings and configuration Connect the two TOR 200 cards with a multi coupling braided unscreened CAT 5 U UTP AWG 24 cable on terminals A B GND...

Page 29: ...to confirm 1 Select 1 and press ENTER to confirm the automatic calibra tion of travel mode The wing barriers will slow down their travel until the stopping strike The wing barriers will invert their t...

Page 30: ...________________________ _________________________________________________________________________________ Extraordinary maintenance Maintenance Before any maintenance jobs cut off the main power to p...

Page 31: ...o nal and market development strategies Just follow these short disposal instructions DISPOSING OF THE PACKAGING The components of the packaging i e cardboard plastic etc are household waste and may b...

Page 32: ...istenza Tecnica Numero Verde 800 295830 www came com www came com English English Manual code 119G3565EN 119G3565EN ver 3 3 07 2013 CAME Cancelli Automatici S p A The data and information in this manu...

Reviews: