ACCESSING TECHNICAL MENU
To start up the system and then programme it by keypad, access
the Installer Menu (hereafter the Technical Menu)
Depending upon the
TECH MENU ACCESS
(
CODES
->
INSTALLER TECHNICAL CODE
)
parameter, access to the Technical Menu may or may not be preced-
ed by the User Code
This parameter can only be changed via PC with PXManager soft-
ware
Simultaneous access from more than one keypad to the
technical or user menu is not permitted The Technical Code can
be changed later
DIRECT ACCESS
(A)
08:23 16/05/10
ENTER CODE
MENU SELECTION
(222222)
To access the Technical Menu directly, the system must be off Key
in the Technical Code and then press key
(A)
If the code has less
than 6 digits, confirm entry of the code with
(*)
ACCESS PRECEDED BY USER CODE
(A)
(B)
08:23 16/05/10
ENTER CODE
WAITING
*=USER MENU
MENU SELECTION
self-learning
(123456)
(222222)
To access the Technical Menu, key in the User Code then the
Technical Code and finally press key
(A)
Press key
(B)
to enter
self-learning The choice of these two menus is available only from
the control unit and not from a remote keypad
If the codes have less than 6 digits, confirm entry of the codes with
(*)
NB IN ALL THE INSTRUCTIONS THAT FOLLOW, THIS OPERATION
WILL ALWAYS BE CALLED
“
GO INTO THE TECHNICAL MENU
”
WITH NO OTHER DETAILS,
SELECTION OF NUMBERS GREATER THAN 9
Some parameters might require the entry of numbers from 10 to
16 To do this you must select "tens" by pressing
(0)
Example: to enter 13, you must press the following keys in se-
quence
(0)
and
(3)
OPENING / CLOSING CONTROL UNIT
When the control unit is opened by removing the cover, the system
goes into alarm mode In order to avoid this, first go into the Tech-
nical Menu
Once the control unit cover is open, if you want to exit the Technical
Menu to do tests, maintenance or reprogramming, the central tam-
per "JP3" must be temporarily excluded
System start-up
Maintenance status is shown in the first row of the display, on the
local keypad and those connected on the Bus
IN MAINTENANCE
ENTER CODE
When maintenance/programming is completed, restore the system
to service, in one of the following ways:
METHOD 1
1 Pass a valid key over the local reader to temporarily disable the
control unit tamper
2 Put the control unit into service, setting Dip 1 to OFF
3 Close the control unit within 30” before the control unit tamper
alarm is activated
METHOD 2
1 Go into the technical menu via the local keypad
2 Put the control unit into service, setting Dip 1 to OFF
3 Close the control unit
4 Exit the technical menu
Service status (shown by the date and time set) is displayed in the
first row of the display, on the local keypad and those connected
on the Bus
08:23 16/05/10
ENTER CODE
ONCE THE CONTROL UNIT IS CLOSED, WAIT FOR THE KEYPAD
BACKLIGHTING TO GO OFF BEFORE USING IT, TO ALLOW FOR ITS
CALIBRATION
In addition, to avoid activating an unwanted siren or telephone
calls, you can disable these by putting the system into maintenance
mode
SYSTEM UNDER MAINTENANCE / OPERATION
Before any maintenance or programming operation, the Control unit
must be put into maintenance status See also
In maintenance mode the control unit disables:
•
Voice calls and SMS
•
Activating alarm outputs
It is still possible, however, to test the disabled functions via the
User Menu and Technical Menu
To activate maintenance status set dip 1 to ON as illustrated
ON
OFF