DIR10U
www.came.com
1.8 in
ø 1.8 in
1
2
3
4
#
#
5
1
1.06 in
ø 0.33 in
1.81 in
0.91 in
3.58 in
4.25 in
IP 54
INFRARED BEAM PHOTOCELLS
COMPONENTS
1. Container
base
2. Electronic
card
3.
Container cover with infrared screen
4.
Cover fastening screw
5. Flush-mounting
base
MOUNTING
A) Fasten the photocells at about 1.7 ft from the
ground (the photocells must face each other).
B) If necessary, set up the fl ush-mounting base
housing
⑤
and fasten it.
C) Fasten the container
①
to the wall or to the base
⑤
using the supplied screws and even plugs,
if required.
D) Select the power-source type and carry out the
necessary connections . Warning: to remove the
card, apply pressure only to the side shown .
Fasten the cover
③
.
NOTE: these photocells do not require any aligning.
Technical Data
Range
33 ft max
Power supply
12 / 24 V AC / DC
Relay contacts rated
1A max a 24 V
Power draw
60 mA - 24 V AC
Material
ABS
Insulation class
Dismantling and disposal
-
Before proceeding it is always
a good idea to check your local legislation on the matter.
The components of the packaging (i.e. cardboard, plastic,
etc.) are solid urban waste and may be disposed of without
much trouble, simply by separating them for recycling. Other
components (i.e. control boards, transmitter batteries, etc.)
may contain hazardous substances. These must therefore be
handed over the specially authorised disposal fi rms.
DO NOT DISPOSE OF IN NATURE!
The data and information in this manual may be changed at any time
and without prior notice.
119RU81
119RU81
- ver.
1.0
1.0
- 07/2012
119RU81
119RU81
- ver.
1.0
1.0
- 07/2012
❶ ->
❷ ->
Connection in REOPENING WHILE CLOSING.
Connection of 2 PAIRS of photocells in REOPENING WHILE CLOSING.
Connection of 2 PAIRS OF photocells:
one in REOPENING WHILE CLOSING
❶
and one in PARTIAL STOP
❷
.
EXAMPLE CONNECTIONS ON CAME CONTROL PANEL