ENGLISH
The electronic card is powered by 230V A.C. on terminals L-N, with maximum 50/60Hz frequency.
The command accessories run on 24V.
Warning! The accessories cannot exceed 40W overall.
All of the connections are protected by quick fuses, see table.
TA B E L L A F U S I B I L I Z B X 8
protecting: fuse:
Electronic card (line) 5A-F
Accessories 1A-F
Command devices (control unit) 315mA-F
Electro-block 1.6mA-F
Batteries 1.6mA-F
Note: if a usually closed safety contact (2-C1, 2-C3 or 1-2) is opened, it is signalled by the fl ashing of the LED indicator (ref. part 9, main
components).
The card provides and controls the following optional functions:
- automatic closing after an opening command;
- pre-fl ashing of the movement indicator;
- obstacle detection with gate stopped at any point;
- constant check of photocell operation.
The defi nable command modes are:
- opening/closing;
- maintained action opening/closing;
- partial opening;
- reopening during closing phase;
- partial stop;
- total stop.
The apposite trimmers regulate:
- the intervention time of the automatic closing;
- the partial opening.
Option to connect a cycle lamp. A lamp lights up the manoeuvring zone, it remains lit from the moment the doors begin to open until they
are completely closed (including the time required for the automatic closure).
WARNING: before intervening inside the equipment, cut off the main power and disconnect the batteries (if inserted).
6.1 General description of the ZBX8 card
DAT I T E C N I C I Z B X 8
Power voltage 230V - 50/60 Hz
Draw when not working 32mA
Maximum power of 24V accessories 40W
Circuit insulation rating II