Page 3: ...ns Protections 22 5 5 1 Inrush Current Limitation 22 5 5 2 Mains Over Voltage Detection 22 5 5 3 Mains Surge Overvoltage Protection 22 5 5 4 Mains Failure Detection 22 5 5 5 Fuse Protection 22 5 6 Mai...
Page 4: ...lcome to the iD Series user manual Please visit our website www camcoaudio com for the latest version of this user manual Please note that the leading version of CAMCO manuals is always the English on...
Page 5: ...low the manufacturer s instructions Only mounting accessory shall be used which is recommended by the manufacturer 5 Mains Connection The amplifier may only be connected to a socket with a protective...
Page 6: ...rom its normal function or performance in case the amplifier has been used in a dusty environment for quite a period of time 14 Servicing All service and repair work must be carried out by a dealer di...
Page 7: ...ERSONNEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL ALERTS THE USER TO DANGEROUSLY HIGH VOLTAGE AT THE OUTPUT CONNECTORS THAT COULD POTENTIALLY BE LIFE THREA...
Page 8: ...cil Directive 2006 95 EC Manufacturer s Name CAMCO Produktions und Vertriebs GmbH f r Beschallungs und Beleuchtungsanlagen Manufacturer s Address Fischpicke 5 D 57482 Wenden Germany Declares that the...
Page 9: ...ise results The CAMCO peace of mind long term manufactures warranty is our commit ment to you that every CAMCO amplifier is ready to give you many years of faultless service WELCOME TO CAMCO 1 1 Unpac...
Page 10: ...oltages of the power amplifier are more stable than the power supplies used in conventional amplifiers The iD4 iD7 has been designed as a powerful two channel amplifier with on board 64 bit DSP proces...
Page 11: ...ter LCD Channel buttons Item buttons Menu buttons Rotary encoder with push button Removable air filter system Cooling air inlet vents On Off switch 2 2 The iD4 Rear XLR line input 1 XLR line input 2 A...
Page 12: ...cter LCD Channel buttons Item buttons Menu buttons Rotary encoder with push button Removable air filter system Cooling air inlet vents On Off switch 2 4 The iD7 Rear XLR line input 1 XLR line input 2...
Page 13: ...power iD4 Amplifier standby power off 0 5 A 8 W 0 W Idle amplifier powered on 1 3 A 70 W 0 W 250 W per channel 9 10 5 A 1220 1500 W 500 W iD7 Amplifier standby power off 0 65 A 18 W 0 W Idle amplifie...
Page 14: ...main power supply can only be achieved by disconnecting the mains plug or by an external all pole disconnection e g a mains circuit breaker The mains plug or circuit breaker therefore has to be freel...
Page 15: ...and washers when mounting the amplifier to the front rack rails For mobile use the amplifier should also be secured using the 19 mounting elements on the rear panel 3 3 1 Mounting Dimensions iD4 3 3 2...
Page 16: ...ows you to access the iD4 iD7 from a host computer for remote control firmware update and downloading DSP presets The iD4 iD7 is configured by default to use DHCP for automatic IP address assignment i...
Page 17: ...d The loudspeaker load must then be connected between the two positive chan nel outputs pin 1 and pin 2 using a specially configured SPEAKON con nector cable This effectively doubles the maximum outpu...
Page 18: ...lay Mute Input DSP 1 1 Mixer Gain Crossover PEQ 10x Compressor Peak Limiter VU Meter Phase Invert Delay Mute Output DSP 1 1 Input Source Selection Gain VU Meter Crossover PEQ 10x Compressor Peak Limit...
Page 19: ...4 5 5 Fuse Protection 5 1 2 Clip LEDs multifunctional The colour of the bi coloured LED changes between orange and red depend ing on the clip intensity Orange indicates light clipping red indicates he...
Page 20: ...red direction In some menus the push function of the encoder will act as an ENTER button for example when loading or saving presets or will allow you to access the parameter s sub settings for the Low...
Page 21: ...at low output impedances smaller 4 and high output powers and shall prevent the ampli fier from being operated in continuous hard amplifier cliping 5 4 2 SOA Protection Whenever the power transistors...
Page 22: ...ds and minutes the average mains current draw can become very high In such situations the FuseProtect limiter will reduce the output signal in order to prevent the external mains breaker from tripping...
Page 23: ...d output levels iD4 iD7 Filter Assembly Foam filter Front frame Screw WARNING Turn off and disconnect the amplifier from the mains before removing the front frame To clean or replace the filter just s...
Page 24: ...put signal is used please check AES signal source samplig frequency bit resolution and signal quality long cables 6 3 Problem Error message Error Amp switched off This error message indicates an inter...
Page 25: ...1 2480 W 16 peak 1 4500 W 8 peak 1 3200 W 4 peak 1 2 760 W 16 1 4 600 W 8 1 6 880 W 4 1 2 980 W 16 peak 1 5 600 W 8 peak 1 7 400 W 4 peak 70 100 V line operation output power 1 kHz THD 1 only possibl...
Page 26: ...tion circuits Inrush current limitation mains surge overvoltage protection temperature monitoring of heatsinks output DC protection temperature dependent SOA protection mains fuse protection output cu...
Page 27: ...used Amplifier output power performance will decrease with lower mains voltages than the rated 230 V 220 V 120 V and slightly increase with higher mains voltages 190 263 V 190 263 V 95 134 V 175 265...
Page 28: ...uency 120 W output power 4 load Measurement of a typical performance of a iD4 iD7 8 3 THD 1 kHz vs input level 2 load 32 dB amplifier gain Measurement of a typical performance of a iD4 iD7 8 4 THD 1 k...
Page 29: ...vs frequency 120 W output power 4 load Measurement of a typical performance of a iD4 iD7 8 7 Channel separation vs frequency 120 W 4 Measurement of a typical performance of a iD4 iD7 8 8 DIM100 vs in...
Page 30: ...Measurement of a typical performance of a iD4 iD7 8 11 Output impedance vs frequency 1 Amp RMS injected current equivalent 11 m 2 1 H Measurement of a typical performance of a iD4 iD7 8 12 Damping fac...
Page 31: ...13 6 8 49 17 78 15 56 4 50 9 00 18 7 9 90 19 12 16 90 6 13 12 25 8 11 31 20 28 18 06 8 00 16 32 9 12 73 21 30 19 08 10 20 41 10 14 14 22 22 20 00 13 25 50 12 16 97 23 80 21 58 18 36 72 15 21 21 25 74...
Page 32: ...by shipping accidents misuse abuse operation with incorrect AC voltage operation with faulty peripheral equipment modification or alteration without prior factory approval service by an unauthorised...
Page 33: ...mplifier the original packing materials must be used Please return the amplifier to the address on the right side or your nearest CAMCO appointed distributor Nature of problem occurred Please describe...
Page 34: ...cient knowledge of all relevant governmental work safety regulations to be in a position to judge the safe functioning of power amplifiers based on technical rules according to IEC 60065 IEC 60065 DIN...
Page 35: ...C O M P A N Y I N F O R M A T I O N Company information Mailing address CAMCO Produktions und Vertriebs GmbH f r Beschallungs und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany Telephone 49 0...
Page 36: ...A M P L I F I E R S C H A N G E S M A D E T O T H E A M P L I F I E R N O T I C E Changes Made to The Amplifier Notices l NOTE IMPORTANT Please consider that any changes made to the amplifier have to...
Page 37: ...3 7 3 8 www camcoaudio com U S E R M A N U A L i D S e r i e s A D V A N C E D A M P L I F I E R S C H A N G E S M A D E T O T H E A M P L I F I E R N O T I C E S...
Page 38: ...M A D E I N G E R M A N Y www camcoaudio com i D S e r i e s A D V A N C E D A M P L I F I E R S...