Once you have pressed this you will be taken to the Internal hub settings section where you can view
and change the Internal hub settings, including reverting back to default factory settings.
Setting
name
Description
Default
value
Friendly
Name
Define the friendly name for this device. Limit of 31 characters. This name
will appear in the device's system information if set.
Empty
Attach
Threshold
(mA)
The attach threshold is the device current (mA) level at which the hub can
determine that a device (iPhone etc.) has been attached to a port. The
attach threshold may need to be increased if the device (iPhone etc.) is
connected to a Cambrionix port with a cable which includes an LED or
other electronics. It may also need to be increased if you are using a
device (iPhone etc.) with a 3rd party sled/holder/case (such as a barcode
scanner or battery pack) which contains electronics or charging pass-
through
10
*Charging Downstream Port (CDP) Being enabled means that a port is capable of transferring data
and charging the device at the same time with a higher current than just data syncing alone. With
CDP enabled the hub can supply up to 1.5A
If you disable CDP
you will receive the notification “This Hub has the Charge Downstream Port UCS
mode disabled. This could limit the maximum current seen on some ports.” This notification is there
to ensure you havent turned this off by accident and can still have the highest charge available.
There is more information on the Internal hub settings
and how to manage them in our CLI
manual.
which can be found at the link
CAUTION
A new version may be available
Ensure you have the latest version of Cambrionix Connect installed on your host
system. These updates will often contain new features, fixes for bugs and
performance improvements
5.4.2 Cambrionix API
The Cambrionix API allows you to monitor and control each port in detail and to integrate these
functions into your own workflow processes. The API comprises a daemon (which is a program
running in the background) that can be downloaded from
www.cambrionix.com/products/api
and
installed on the host machine. Port information and control can be provided through the API. Calls are
sent as a request to the API to “Get” port, device or Hub information, or “Set” port functions. A library