OEM PDS-C4
Page 11 of 35
4.4. Connecting the OEM PDS-C4 to the Power Supply Unit
using Spade Connectors
Having ensured the output voltage of the DC power supply is 21V Maximum, and certainly does
not exceed 5.6 Vdc, connect the PSU to the OEM PDS-C4 using insulated copper cables of no
less than six mm2 cross-section and no longer than 150 mm. Longer cables or smaller cross-
sections are likely to cause a voltage drop across the cable and improper board operation.
With the mains power supply disconnected, the PSU should be connected to the input spade
terminals on the OEM PDS-C4 using the cable (described above) terminated (at the OEM PDS-
C4 end) with crimp connectors. The positive voltage spade terminal is closest to the OEM PDS-
C4 board edge, and Ground (GND) is marked on the OEM PDS-C4 board close to the innermost
spade terminal.
Taking appropriate safety precautions, turn the mains supply on. Periodic inspection should be
made to power supply cables and any USB cables for any signs of damage. If any damage is
found then replace damaged cord before further use.
4.5. Registration
You may register your product at
www.cambrionix.com/product-registration
4.6. Help and Support
FAQs and help can be found on the Help page here
l
www.cambrionix.com/help_pages/help
.
You can raise a support ticket for more in depth support here
l
https://cambrionix.atlassian.net/servicedesk/customer/portals
You can also download any of our manuals and keep up to date at the link here
l
www.cambrionix.com/product-user-manuals
When contacting support, please supply the product information for the hub in question. This
can be found on the Device Information Plate which is either on the underside or back of the
unit. Including serial and Purchase order numbers, can help identify the product in question
faster, and speed up the process.