![Cambium PTP 670 Series User Manual Download Page 422](http://html.mh-extra.com/html/cambium/ptp-670-series/ptp-670-series_user-manual_485665422.webp)
Chapter 6: Configuration and alignment
System menu
Page 6-63
Table 171 TDM Configuration attributes
Attribute
Meaning
TDM Interface Control
TDM Local MAC Address Display only. MAC address of the local NIDU.
TDM Remote MAC
Address
Display only. MAC address of the remote NIDU.
License Max Number of
TDM Channels
TDM Enabled Channels
TDM Channel Line Code
n
TDM Channel Cable
Length n
TDM Channel Loopback
n
Select the loopback status of TDM channel “n” (where “n” is in
the range 1 to 8).
None: Normal operation, no testing is required.
Copper: Sends the TDM data received from the local transceiver
and NIDU back on the same TDM channel. This may be used in
conjunction with a Bit Error Rate Tester to confirm that the
correct connections have been made between the transceiver,
NIDU and ODU. This mode cannot be used for resistance tests,
as it is only capable of looping back valid TDM signals.
Wireless: Sends the TDM data received from the wireless link
back across the link on the same TDM channel. The link may be
checked using, for example, a Bit Error Rate Tester to ensure
that no errors are detected.
Lowest TDM Modulation
Mode
Authorization Control page
Menu option: System > Configuration > Authorization Control (
Authorization control is used when Access Method is configured to Group Access, and
Encryption Algorithm is configured to TLS-RSA. In the HCMP topology, Group Access is the
only Access Method supported. In the PTP topology, Group Access is available only with the
Group Access license. The Authorization Control page is hidden if it is not applicable.
When Authorization Method is configured to Whitelist, the ODU will connect only if the
authenticated MAC address of the remote unit is in the list of authorized ODUs. With the
Blacklist option, the ODU will always connect unless the authenticated MAC address has been
added to a list of unauthorized ODUs.
The Authorization Control page allows up to 32 MAC addresses to be entered.