Before starting an installation, use a leveler to make sure that the poles are 100% vertical. You need to check both
sides of each pole at 90 degrees separation. This is a critical step in any link but most important when installing
XPIC.
Torque Requirements
When tightening the captive screws, use 20 Nm torque for radio-antenna, radio-mediation device, and mediation
device-antenna connections. In order to avoid tilt, screws should be tightened progressively.
When fastening a waveguide to the radio or mediation device, use the following torque, according to frequency
and screw type:
•
6 GHz: M5/#10-32: 3.5 Nm
•
7/8-15 GHz: M4/#8-32: 2.5 Nm
•
18-42 GHz: M3/#4-40: 1Nm
Remote Mount Installation with Imperial Waveguide
List of Items
Table 11
Required items for Remote Mount Installation with Imperial Waveguide
Item Description
Quantity
Remarks
1
RFU-C RADIO
1
2
RFU-C REMOTE MOUNT ADAPTOR KIT
1
Up to 15 GHz
3
RFU-C REMOTE POLE MOUNT KIT
1
Required Tools
•
Metric offset hexagon key wrench set
•
Imperial offset hexagon key wrench set
Remote Mount Installation – 6-11 GHz
1
Mount the RFU-C Adaptor supplied with the RFU-C Adaptor kit on the RFU-C Remote Pole Mount kit using
the four flat screws supplied with the RFU-C Adaptor kit.