Performing Fine Azimuth Adjustment
To perform fine azimuth alignment:
1.
Turn the Azimuth Nut (Figure 28), either by hand or using a key wrench, for fine tuning of the azimuth.
Each ¼ turn is equal to an adjustment of 0.25°.
2.
Tighten the two M8 Azimuth Screws connected to the azimuth base.