Chapter 12: Alarm Management and Troubleshooting
Configuring External Alarms
phn-3965_006v002
Page 12-14
In addition to adding the ability to configure these alarm thresholds, Release 10.9 adds PMs that indicate, per 15-
minute and 24-hour periods:
•
The number of seconds the unit was in an undervoltage state during the measured period.
•
The number of seconds the unit was in an overvoltage state during the measured period.
•
The lowest voltage during the measured period.
•
The highest voltage during the measured period.
These PMs are displayed via CLI. For instructions, see
Configuring Voltage Alarm Thresholds and Displaying Voltage
Configuring the Output Alarm
To enable and configure the output alarm:
1
Select
Platform > Management > External Alarms > Output
. The External Alarms Output page opens.
Figure
External Alarms Output Page
2
In the
Admin
field, select
enable
to enable the output alarm or
disable
to disable the output alarm.
3
In the
Group
field, select from a list of alarm groups, or select
all groups
. When an alarm belonging to the
selected group is raised, the alarm output is triggered. The available alarm groups are:
o
Communications
o
Quality of Service
o
Processing
o
Equipment
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...