Chapter 12: Alarm Management and Troubleshooting
Configuring External Alarms
phn-3965_006v002
Page 12-10
Configuring External Alarms
PTP 820G and PTP 820F includes a DB9 dry contact external alarms interface. This interface is located on the front
panel. See
shows the pin-outs for the external alarms interface.
Table 122
External Alarms Interface Pin-Outs
Pin Number
Description
1
External Input Alarm #1
2
External Input Alarm #2
3
External Input Alarm #3
4
External Input Alarm #4
5
External Input Alarm #5
6
Relay #1, normally closed pin
7
Relay #1, common pin
8
Relay #1, normally open pin
9
GND
Configuring Input Alarms
To enable and configure the input alarms:
1
Select Platform > Management > External Alarms > Input. The External Alarms Input page opens.