Chapter 9: TDM Services and Interfaces
Configuring TDM Pseudowire Services
phn-3965_006v002
Page 9-38
14
In the
Protecting EC ID
or
Working EC ID
field, select an EC ID (1-512) to identify the protecting or working
path. Only unused EC ID values appear in the selection box. The default value is the lowest unused EC ID. All
nodes in the protected configuration, both on the protected and the protecting path, must have the same
Protecting EC ID
or
Working EC ID
.
15
Click
Finish
. The Selection Summary page opens, displaying the parameters you have configured.
Figure 315
Pseudowire Service Creation
–
Selection Summary Page (Radio/Ethernet/Cascading - TDM)
16
To create the service with the displayed parameters, click
Submit
. If you want to return to an earlier page
and change the service parameters, click
Back
.
Note
An invalid configuration error may occur in the event that another user utilized a resource that you
selected, such as an interface or a EC ID, between the time you selected the resource and the time
you pressed
Submit
. If this occurs, you must go back and, if necessary, select alternative resources
for the service.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...