Chapter 8: Ethernet Protocols
Configuring G.8032
phn-3965_006v002
Page 8-9
Configuring Timers
You can configure timers per ERPI to control the ERPI's switching and convergence parameters. The following
timers are available:
•
Wait to Restore (WTR) Timer
–
Defines a minimum time the system waits after signal failure is recovered
before reverting to idle state.
•
Guard Time
–
Prevents unnecessary state changes and loops.
•
Hold-Off Time
–
Determines the time period from failure detection to response.
To configure the ERPI timers:
1
Select
Ethernet > Protocols > G.8032 > ERPI Attribute
. The G.8032 ERPI Attribute page opens (
2
Select the ERPI and click
Edit
. The ERPI Attribute
–
Edit page opens (
3
In the
ERPI WTR
field, enter the Wait to Restore (WTR) timer (in minutes). The WTR timer is a minimum
time the system waits after signal failure is recovered before reverting to idle state.
4
In the
ERPI Guard Time
field, enter the ERPI guard time (in msec). You must enter a multiple of 10. The
guard time is the minimum time the system waits after recovery from a signal failure before accepting new
R-APS messages. The purpose of this timer is to prevent unnecessary state changes and loops.
5
In the
ERPI Holdoff Time
field, enter the ERPI hold-off time (in msec). You must enter a multiple of 100. The
hold-off time determines the time period from failure detection to response.
6
Click
Apply
, then
Close
.
Viewing the ERPI Configuration and Status Parameters
The G.8032 ERPI Attribute page (
) displays some of the configuration and status parameters for ERPIs
configured in the system.
To display a full list of configuration and status parameters for an ERPI:
1
Select
Ethernet > Protocols > G.8032 > ERPI Attribute
. The G.8032 ERPI Attribute page opens (
2
Select the ERPI and click
Edit
. The ERPI Attribute
–
Edit page opens (
o
lists and describes the parameters in the ERPI configuration section of the ERPI Attribute
–
Edit
page.
o
lists and describes the parameters in the ERPI status section of the ERPI Attribute
–
Edit page.
Table 72
Attached Interface Types
Parameter
Definition
ERPI ID
Read-only. A unique ID that identifies the ERPI.
ERPI Name
A descriptive name for the ERPI.
ERPI Type
Read-only. The ERPI type.
ERPI Service ID
Read-only. The ID of the Ethernet service to which the ERPI belongs.
Instance ID
Read-only. The MSTI to which the Ethernet service is mapped. See
Ethernet Services to MSTP instances (MSTIs)
West ERPI Port (SP)
Read-only. The interface to which the west ERPI service point belongs.
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...