Chapter 7: Quality of Service (QoS)
Configuring Egress Shaping
phn-3965_006v002
Page 7-29
Figure 238
Queue Shaper Profile Page
2.
Click
Add
. The Queue Shaper
–
Add page opens, with default values displayed.
Figure 239
Queue Shaper Profile
–
Add Page
3.
In the
Profile ID
field, select a unique ID to identify the profile. Permitted values are 1-31.
4.
Optionally, in the
Description
field, enter a description of the profile.
5.
In the
CIR
field, enter the Committed Information Rate (CIR) assigned to the profile, in bits per second.
Permitted values are:
o
16,000 - 32,000,000 bps, with granularity of 16,000.
o
32,000,000 - 131,008,000 bps, with granularity of 64,000.
6.
Click
Apply
, then
Close
.