Chapter 29: Alarms List
Unit/ACT LED
–
PTP 820F
phn-3965_006v002
Page 29-1
Chapter 29:
Alarms List
The following table lists all alarms used in the PTP 820G and PTP 820F products.
Alarm ID
Name
Type
Description
Severity
Probable Cause
Corrective Action
10
radio-digital-loopback
Alarm
Framer digital loopback
Warning
User enabled framer
digital loopback.
Disable framer digital
loopback.
25
main-board-extreme-
temperature-alarm
Alarm
Unit Temperature is out of
system specified limits.
Warning
26
main-board-low-
voltage-alarm
Alarm
Unit input voltage is too low.
Warning
27
main-board-high-
voltage-alarm
Alarm
Unit input voltage is too high.
Warning
28
main-board-warm-
reset
Event
Unit warm reset.
Indeterminat
e
29
main-board-cold-
reset
Event
Unit reset.
Warning
30
main-board-poe-low-
voltage-alarm
Alarm
POE input voltage is too low
Warning
31
Event
Change Remote request was
sent
Major
32
Event
Protection switchover due to
remote request
Major
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...