Installation Guide for RFU-D-HP
Page 73 of 179
Important Note!
Verify that the O-rings are correctly mounted between the OMT ports and each flexible waveguide.
Mount and tighten the RFU-D-HP DC pole mount to the pole using the four washers and screws supplied with the RFU-
D-HP DC pole mount kit:
o
For 4-5 GHz configurations, use 39 Nm torque
o
For 6-11 GHz configurations, use 39 Nm torque
Figure 31: Remote Pole Mount Kit
–
6-11 GHz
Figure
32
: Remote Pole Mount Kit
–
4-5 GHz
Mount and tighten the RFU-D-HP Remote Mount Adaptor plate (supplied in RFU-D-HP Adaptor Remote Mount kit) to
the RFU-D-HP Pole Mount using the four flat screws supplied with the RFU-D-HP Adaptor Remote Mount kit.