Chapter 5: Installation
271
When preparing the drop cable for connection to the 450 Platform PSU (without a cable gland), use the
following measurements:
Cr eat ing a d r op cab le g r ound ing p oint
Use this procedure to connect the screen of the main drop cable to the metal of the supporting structure
using the cable grounding kit (Cambium part number 01010419001).
To identify suitable grounding points, refer to Hazardous locations.
1
Remove 60 mm (2.5 inches) of the drop cable outer sheath.
2
Cut 38mm (1.5 inches) of rubber tape (self-amalgamating) and fit to the ground cable lug. Wrap the
tape completely around the lug and cable.