Connecting 60 GHz cnWave™ Products
38
Installing the 60W DC power injector
1. Connect the Input side of DC power Injector to AC power line.
Figure 1 :
60W DC power injector
2. Connect 5 Gbe LAN port of the power injector to network equipment.
3. Connect 60 W 56V 5 GbE PoE port of the power injector to ODU drop cable.
Installing the AC/DC PSU
1. Connect input side of the AC/DC PSU to AC power line.
2. Connect output side of DC PSU to ODU through cable joiner and DC mini adapter. Refer
60 GHz
cnWave™ User Guide for connecting, installing Cable joiner and Mini adapter.
Figure 2 :
AC/DC PSU
Figure 3 :
Cable joiner
Figure 4 :
DC to
RJ45 plug, Mini
adaptor