Page 1: ...1 Instruction Manual www calyxaudio com...
Page 2: ...e not able to reach so far Calyx is the by product of such an effort based on D A s many experiences like designing manufacturing and selling of class D ICs and supporting its customers to make their...
Page 3: ...3 Contents 1 WARNINGS 4 2 Unpacking 5 3 Preparation 5 4 Description of Functions 6 5 Connection Diagram 8 6 Guaranteed Specifications 11 7 Trouble shootings 16 8 Warranty 17...
Page 4: ...can result in a risk of fire or electric shock Do not expose the unit to direct sun radiation or other heat sources This could lead to overheating and malfunction of the unit During thunderstorms dis...
Page 5: ...ridged mono mode as its power is increased 4 times The Calyx FEMTI Amplifier is designed to be very stable but the unit may generate some heat after a prolonged period of operation Rest assure that is...
Page 6: ...el when you see from the front Press once to turn the unit on and once more to turn it off 2 LED Violet The violet LED light indicates that the amplifier is normal status Blue The blue LED turns on if...
Page 7: ...to speaker output terminal Do not use the unit with any other than the supplied power cords The shape of the AC inlet and the plug of the supplied power cord depend on the voltage rating and destinat...
Page 8: ...to preamplifier take care to connect Left input from Left output and Right Select the Output Mode Selector switch located on the rear to S After ensuring all connection turn the Calyx FEMTI Amplifier...
Page 9: ...preamplifier using RCA cable Input connection is located on the rear left labeled or L Select the Output Mode Selector switch located on the rear to M After ensuring all connection turn the Calyx FEM...
Page 10: ...rear left labeled or L Select the Output Mode Selector switch located on the rear to B Loudspeaker connection should be connected to the BRIDGED and BRIDGED Make sure to connect the and and and betwe...
Page 11: ...PUT SENSITIVITY STEREO 125W 1 3V BRIDGE 500W 1 3V DAMPING FACTOR 500 STANDBY POWER CONSUMPTION 10W POWER REQUIREMENT AC100 120V AC210 230V 50 or 60Hz The voltage is fixed when factory out FUSE TYPE T6...
Page 12: ...Stereo Mode Bi Wiring Mode 5 2 4 75 4 5 4 25 4 3 75 3 5 3 25 3 2 75 2 5 2 25 2 1 75 1 5 1 25 1 0 75 0 5 0 25 0 0 25 0 5 0 75 1 1 25 1 5 1 75 d B r A 10 100k 20 50 100 200 500 1k 2k 5k 10k 20k 50k Hz...
Page 13: ...onse Bridged Mono Mode 5 2 4 75 4 5 4 25 4 3 75 3 5 3 25 3 2 75 2 5 2 25 2 1 75 1 5 1 25 1 0 75 0 5 0 25 0 0 25 0 5 0 75 1 1 25 1 5 1 75 d B r A 10 100k 20 50 100 200 500 1k 2k 5k 10k 20k 50k Hz Test...
Page 14: ...14 Calyx Femti THD N vs Watt Stereo Mode Bi Wiring Mode 0 003 1 0 005 0 01 0 02 0 05 0 1 0 2 0 5 T H D N 300m 200 500m 1 2 5 10 20 50 100 Output Power W Test Condition Freq 1kHz Load 4ohm...
Page 15: ...15 Calyx Femti THD N vs Watt Bridged Mono Mode 0 004 6 0 005 0 01 0 02 0 05 0 1 0 2 0 5 1 2 5 T H D N 700m 500 1 2 5 10 20 50 100 200 Output Power W Test Condition Freq 1kHz Load 4ohm...
Page 16: ...in No sound or Level is low Check whether the source component is turned on Check output mode selector setting Check if all cables are connected correctly Sound is briefly interrupted Check for conta...
Page 17: ...es the purchaser must pay the service charge to repair the product 1 After the warranty period has expired 2 Although the warranty period has not expired the purchaser must pay the service charge in t...