Calyenty RBH 125 Customer'S Manual Download Page 1

 

Calyenty

 

                Swimming Pool Heat Pumps 

 

Customer Manual, RBH125 SUPER, RBH185 SUPER 

Thank you for choosing a Calyenty Heat pump. 
 

Contents 

1. Quick reference: 

 

 

 

 

 

2. 

1.1 Controller screen:  

 

 

 

 

 

2. 

1.2 Circulation/filtration pump timer/clock:   

 

 

 

3. 

 

2. Installation: 

 

 

 

 

 

4. 

2.1 Materials to required to install your Calyenty heat pump, you will need:   

4. 

2.2 Tools:   

 

 

 

 

 

 

4. 

2.3 Where to put the heat pump in the hydraulic system: 

 

 

5. 

2.4 Multiple heat pump installations: 

 

 

 

 

6. 

2.5 Installation Procedure: 

 

 

 

 

 

7. 

2.6 Connecting to the electricity supply: 

 

 

 

 

9.  

 

3. Initial Startup: 

 

 

 

 

 

11 

 

4. Usage:   

 

 

 

 

 

12. 

4.1 Control panel: 

 

 

 

 

 

 

12. 

4.2 Start up procedure: 

 

 

 

 

 

12. 

 

5. Backwashing the pool/sand filter:   

 

 

 

13. 

 

6. Maintenance and Troubleshooting: 

 

 

 

13. 

6.1 Maintenance: 

 

 

 

 

 

 

13. 

6.2 Troubleshooting:   

 

 

 

 

 

14. 

7. Error codes and what to do: 

 

 

 

 

15. 

 
 

8. Defrosting: 

 

 

 

 

 

17. 

 
9. Model Data: 

 

 

 

 

 

18. 

 
 
 
10. Exterior  Features:  

 

 

 

 

19. 

11. Interior Features:   

 

 

 

 

20. 

 

12. General Information: 

 

 

 

 

 

21. 

 

 

12.1 Features: 

 

 

 

 

22. 

 

 

12.2 Notes  

 

 

 

 

21. 

 

 

12.3 Energy Saving Tips: 

 

 

 

22. 

 
13. Mounting the Temperature sensor: 

 

 

 

 

23. 

14.  Warranty: 

 

 

 

 

 

 

25.

 

 

Summary of Contents for RBH 125

Page 1: ...ulic system 5 2 4 Multiple heat pump installations 6 2 5 Installation Procedure 7 2 6 Connecting to the electricity supply 9 3 Initial Startup 11 4 Usage 12 4 1 Control panel 12 4 2 Start up procedure...

Page 2: ...the information about specifications installation debugging operation and maintenance Please read this manual carefully before you install start repair or service the unit Professional technicians mus...

Page 3: ...mp runs for 6 8 hours a day during the day i e from 10 00am until 6 00pm This coincides with the optimum time settings for the running of the heat pump too As the ambient air temperature drops into th...

Page 4: ...ible uPVC solvent and cement Adequate 2 5mm x 3 core flexible electrical cable You may find that you need some more pressure fittings or 45 elbows depending on where you position the heat pump in rela...

Page 5: ...system The unit is generally installed outdoors for indoor installation please consult Calyenty Install the unit downstream of all pumps and filters and upstream of all chlorinators ozonizers and che...

Page 6: ...6 Where more than one heat pump is to be installed it is essential that they are connected to the water system in parallel see diagram below 2 5 Installation Procedure...

Page 7: ...nstallation procedures have not having been adhered to 6 Choose a suitable location for your heat pump Remember this must satisfy your aesthetic requirements should be close to the filter pump be on f...

Page 8: ...r as this starts the chemical reaction to ensure a good bond when the adhesive is applied Make sure that the adhesive covers 100 of both surfaces that are to come in contact with each other 9 Connect...

Page 9: ...st be equipped with a breaker which is located within sight and accessible from the unit The unit must be well earthed Several screws fix the electrical component front panel cover to the cabinet Unsc...

Page 10: ...10...

Page 11: ...start delay which can be from just a few seconds to several minutes This feature reduces load on your power supply which irrespective of the electrical consuming device is always significantly more on...

Page 12: ...once to set HOUR by pressing up down arrow n b it is a 24 hour clock Press timer button again to set MINUTES There is a timer built into this controller that is now obsolete It is very important that...

Page 13: ...suitable period usually around a minute Switch off the filter pump and re open the taps back to the pool return Change the multi port selector back to its normal filter position Switch the filter pum...

Page 14: ...t be obstruction of air Environment problem Under certain external conditions the heat exchanges between the refrigerant and the water on one hand and between the fluid and the air on the other hand a...

Page 15: ...ot closed Replace it if damaged 2 There is no water in the pipe hence the water flow circuit is not closed Check if there is water in the water tank 3 The blade in the water flow switch seizes up Repl...

Page 16: ...r is running but the compressor and water pump do not start 2 Phase sequence board is damaged Replace the phase sequence board 1 No power input Plug in the power cord 2 Power voltage is not correct St...

Page 17: ...r will stop but the compressor and pump will continue working Defrost Cut out Conditions when either of the following conditions are satisfied a Evaporator Coil Temperature Defrost Cut out Temperature...

Page 18: ...18 9 Model Data...

Page 19: ...19 10 Exterior Features...

Page 20: ...20 11 Interior Features...

Page 21: ...ily set on the small digital control panel which is designed with a clear and operator friendly style Compact size Calyenty swimming pool heat pump is much smaller than the other products of the same...

Page 22: ...e pool water at your expected temperature or a little lower If you don t use the pool for a long period turn the unit off Please turn the unit off during the winter and drain out all the water by remo...

Page 23: ...to protect the sensor cable 4 Drill a 10mm hole at a suitable point in the water inlet pipe close to the side of the heat pump see photo below 5 Connect the saddle bracket to the inlet water pipe so...

Page 24: ...24...

Page 25: ...4 Abuse alteration accident fire flood lightning rodents insects negligence or acts of God 5 Scaling freezing or other conditions causing inadequate water circulation 6 Operating the product s at wate...

Page 26: ...ing the claim and to determine the location of the nearest designated service center If the dealer is not available you can locate a service center in your area by visiting by calling our technical su...

Reviews: