AFX SERIES® OPERATION MANUAL
SECTION 6:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 100 of 402
6.4
PROG – PROGRAM Screens
All output parameters can set from the PROGRAM screen. This screen has a list of available
parameters on the main PROGRAM screen. Each parameter can be changed by highlighting
the field and either slewing the value using the shuttle knob or entering a value using the
numeric key pad. The difference between these two data entry modes is that slewing
causes the output to change as the knob is turned while using the keypad allows one or
more parameters to be preset to a new value which won’t become active until the “Apply
All” soft key or the ENTER key is pressed.
Thus to slew a value, proceed as follows:
1.
Use shuttle to move the active field to the parameter you want to slew.
2.
Press the shuttle once to enter the slew mode. The selected field will be
highlighted.
3.
Use the shuttle to increment (clockwise) or decrement (counterclockwise) the
selected parameter. Note that these changes take effect immediately resulting in
the active output slewing up or down.
Note: This assumes the output is ON. If the output is OFF, the new value will be in effect
and apply at the output as soon as the output is turned ON.
To slew a parameter while observing the MEASUREMENT screen, proceed as follows:
1.
Use shuttle to move the selected field to the parameter you want to change.
2.
While on the desired parameter (e.g. Voltage or Frequency), DOUBLE-PRESS the
shuttle (similar to double clicking a mouse button).
3.
The MEASUREMENT screen will appear with the parameter to be slewed visible in
the header bar.
4.
Use the Shuttle to slew the parameter up or down. The value will be displayed in the
header bar of the measurement menu.
5.
When done, press the PROGRAM key to return to the regular PROGRAM screen and
exit this interactive mode.
With the parameter field selected, enter a new value using the numeric keypad.
To change one or more values but not change the actual output till all parameters are
preset, proceed as follows:
6.
Use shuttle to move the selected field to the parameter you want to change.
7.
With the parameter field selected, enter a new value using the numeric keypad.
Note that all fields are now shown with a gray background (Edit mode active)
8.
Once satisfied with the new value, move to the next parameter you want to change.
9.
Once all values are set to the new desired set value, press the ENTER key or the
“Apply All” soft key.