CS3000 User’s Guide
Calsense
55
2.
If there is more than one Mainline, select which mainline to schedule to open.
3.
For Open Time, use
+/-
to set the time to open the master valve.
4.
For Close Time, use
+/-
to set the time to override to end.
Performing a Station Inspection/Walk-Thru
The Walk-Thru feature provides the ability to perform a site inspection by turning on stations one-by-
one in a specific order.
Note:
A Walk-Thru cannot combine stations across multiple controllers. If performing a site inspection of
multiple controllers on a
FLOWSENSE
chain, create a separate Walk-Thru for each controller and start
one after the other completes.
To perform a Walk-Thru (Figure 44):
1.
From Main Menu, navigate to
Manual & Test
and select
Walk-Thru
. The Walk-Thru screen
displays.
2.
Navigate to and select the desired Walk Thru program or select
Add Walk-Thru
.
3.
For Walk-Thru name, press
SELECT
and enter a name to uniquely identify the program using the
on-screen keyboard.
4.
For Start walk-thru in, use
+/-
to select when to start the Walk-Thru. This should be enough time
for you to walk to the first station.
5.
For Run each station for, use
+/-
to set how long to run each station for.
6.
For Stations attached to, use +/- to select which controller the Walk-Thru is being created for.
7.
In the list of stations, use
+/-
to add/remove stations and specify what order to run in.
8.
Select
Start Walk-Thru
to start the countdown. Once the countdown completes, the first valve
in the sequence turns on.
9.
If it is necessary to cancel the countdown, select
Stop Countdown
.
Note:
If other irrigation is running when a Walk-Thru starts, the other irrigation will be paused until the
Walk-Thru completes.
Figure 44: Walk-Thru Screen