3.1. Suction pipe

If the suction pipe is longer than 10 m, use an
internal pipe diameter larger than the pump
suction connection.
The suction pipe must be perfectly airtight and be
led upwards in order to avoid air pockets.

With a

pump located above the water level

(suction lift operation, fig. 1A) fit a foot valve with
strainer which must always remain immersed.

With the

liquid level on the suction side above

the pump 

(inflow under positive suction head,

fig. 1B) fit an inlet gate valve.
For suction from a storage tank fit an anti-backflow
valve. 
Follow local specifications if increasing network
pressure.

Install a strainer on the suction side of the
pump to prevent foreign particles from
entering the pump.

3.2. Delivery pipe

Fit a gate valve in the delivery pipe to adjust
delivery, head and absorbed power. 
Install a pressure gauge between the pump and
the gate valve.

ATTENTION:

install a check valve between the

pump and the gate valve in order to avoid rever-
se flow after switching off the pump unit and to
protect the pump from water hammers.

With servooperated shut-off devices, provide an
air vessel or another protection device against
surge of pressure in the case of sudden changes
of flow rate.

4. Electrical connection

Electrical connection must be carried

out only by a qualified electrician in
accordance with local regulations.

Follow all safety standards.

The unit must be properly earthed (grounded).  

Make sure the frequency and mains voltage
correspond with the name plate data. 

The motors with supply cur-
rent directly switched by ther-
mally sensitive switches can
start automatically.

Install a 

device for disconnection from the

mains

(switch) with a contact separation of at

least 3 mm on all poles.

4.1. Single-phase pumps MXSUM

Supplied with incor-
porated thermal pro-
tector.
The motor will stop
if overheating is de-
tected. When the win-
dings cool down (af-
ter 2 to 4 minutes),
the thermal protector
enables re-starting.

Control box with ca-
pacitor supplied on 
request.

Electrical diagram

4.2. Three-phase pumps MXSU

Install in the control box an overload-protective
device in accordance with the name-plate current.

5. Starting

ATTENTION: never run the pump dry - not
even for a short trial run.

Start the pump after filling it completely with liquid.

When the pump is located above the water
level

(suction lift operation, fig. 1A) or with a

positive suction head which is too low (less than
1 m) to open the non-return valve, fill the suction
pipe and the pump through the priming hole
(ref. 6, fig. 1).

6

Fig. 2   Pump supported by the pipes

4.93.177.1

4.93.002/1

M

1

maroon

green/yellow

black

grey

Summary of Contents for MXSU

Page 1: ...llulaires verticales monobloc Bombas multicelulares verticales monobloc MXSU ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano ORIGINAL OPERATING INSTRUCTIONS Page 5 English ORIGINAL BETRIEBSANLEITUNG...

Page 2: ...erdita di liquido potrebbe verificar si in seguito ad una sovrapressione o colpo d arie te per errate manovre es mancata chiusura di un tappo o valvola o per altre disfunzioni Prevedere la possibilit...

Page 3: ...ariazione della portata 4 Collegamento elettrico Il collegamento elettrico deve essere eseguito da un elettricista qualificato nel rispetto delle prescrizioni locali Seguire le norme di sicurezza Eseg...

Page 4: ...svuotata completamente se esiste il pericolo di gelo Prima di ogni intervento di manuten zione togliere l alimentazione elettri ca e assicurarsi che la pompa non rischi di essere messa sotto tensione...

Page 5: ...sult of overpressure water hammer erroneous opera tions such as failing to close a plug or valve or other functional disorders Allow for the possibility of channeling away any leaked fluid or for an a...

Page 6: ...low rate 4 Electrical connection Electrical connection must be carried out only by a qualified electrician in accordance with local regulations Follow all safety standards The unit must be properly ea...

Page 7: ...e pump cannot be accidentally switched on 7 Dismantling 7 1 Checking rotation of the shaft Close the suction and delivery gate valves and drain the pump casing before dismantling the pump For dismantl...

Page 8: ...s Drucksto es eines Wasserschlags fehlerhafter Man ver z B ausbleibender Verschlu einer Verschlu schraube oder eines Ventils oder anderer Fehlfunktionen auftreten F r den Fall einer Leckage ist eine A...

Page 9: ...s Membrandruckbeh lters auf der Pumpendruckseite 4 Elektrischer Anschlu Der elektrische Anschlu ist von Fachpersonal unter Beachtung der rtlichen Vorschriften auszuf hren Sicherheitsvorschriften befol...

Page 10: ...fuhr durchf hren und sich versichern da die Pumpe nicht aus Unachtsamkeit unter Spannung gesetzt werden kann 7 Demontage 7 1 Kontrolle der Wellenumdrehung Vor Demontage Absperrorgane vor und hinter de...

Page 11: ...ou aux biens La cause de perte de liquide peut provenir d une surpression d un coup de b lier ou erreur de man uvre ex un bouchon ou une vanne pas ferm s ou autres dysfonctionnements Prevoir la possib...

Page 12: ...soudaines de d bit 4 Connexion lectrique La connexion lectrique doit tre ex cut e par un sp cialiste suivant les prescriptions locales Suivre les normes de s curit Ex cuter la mise la terre Comparer...

Page 13: ...tre vid e compl tement s il existe un danger de gel Avant toute op ration d entretien d brancher l alimentation lectrique et s assurer que la pompe ne risque pas d tre mise sous tension par inadverta...

Page 14: ...da de l quido se puede originar debido a una sobre presi n por un golpe de arie te por una maniobra err nea ej falta del cierre de un tap n o v lvula o por otra disfunci n Prevenir la posibilidad de e...

Page 15: ...Conexionado el ctrico El conexionado el ctrico tiene que ser realizado por un electricista cualificado y cumpliendo las prescripciones locales Seguir las normas de seguridad Realizar la toma a tierra...

Page 16: ...intervenci n de man tenimiento cortar la alimentaci n el ctrica y asegurarse que la bomba no corre riesgo de ser arrancada bajo tensi n por descuido 7 Desmontaje 7 1 Control de la rotaci n Antes del d...

Page 17: ...MXSU 1 35 C 60 3 10 30 60 2 1 3 2 2 8 9 9 9 9 A B 5 3 4 2 9 9 7 8 10 1 4 1 3 4 93 177 6 1 2 1 2 3 4 8 5 6 7 8 9 10 17...

Page 18: ...2 3 1 B 10 2 1A 1B 0 3 2 2 B 4 F G 9 H 3 4 1 0 MXSUM 2 4 4 2 0 MXSU 2 5 6 8 1A 1 4 93 177 1 4 93 002 1 M 1 18...

Page 19: ...G 6 1 0 G H 9 G 2 2 5 6 2 G 7 7 1 14 24 14 28 61 00 16 00 16 30 25 01 28 04 B 7 2 9 I 14 02 14 20 25 01 28 04 28 08 64 15 28 00 25 02 25 05 7 3 B 2 34 03 36 00 70 18 34 03 9 35 36 00 34 03 70 00 70 09...

Page 20: ...2 03 82 04 82 01 72 00 72 02 25 05 34 03 25 02 25 01 28 08 28 04 16 00 96 00 70 16 70 05 70 13 70 12 82 05 70 00 78 12 70 18 70 09 36 52 36 51 64 15 14 20 14 28 14 29 14 24 78 00 73 00 92 00 81 00 76...

Page 21: ...54 Spacer 40 00 Radial shaft seal 61 00 Base 64 10 Bearing sleeve 64 15 Spacer sleeve 64 19 Spacer sleeve bearing stage 70 00 Motor cover pump side 70 05 O ring 70 09 O ring 70 10 O ring 70 12 Cable g...

Page 22: ...8 14 06 14 20 14 24 2 14 28 14 29 J 14 54 1 16 00 16 30 25 01 25 02 25 03 25 05 25 10 2 28 00 28 04 28 08 J 34 03 36 00 36 51 2 36 52 36 54 40 00 61 00 64 10 2 64 15 64 19 70 00 70 05 70 09 70 10 70 1...

Page 23: ...er fremstillet i overensstemmelse med bestemmelserne i Direktiv 2004 108 EC 2006 42 EC 2006 95 EC og er i ove rensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar...

Page 24: ...DIESE BETRIEBSANLEITUNG AUFBEWAHREN CONSERVER CES INSTRUCTIONS CONSERVAR ESTAS INSTRUCCIONES 9 A 6B Calpeda s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 Fax...

Reviews: