background image

Page 15 / 80

GQ, GX, GM Rev. 5 - Operating Instructions

GB

PROBLEM 

1) The engine

does not
start

2) Pump

blocked

3)The pump

functions
but no water
comes out 

4) Insufficient

flow

5) Noise and

vibrations
from the
pump

6) Leakage

from the
mechanical
seal

PROBABLE CAUSES

1a) Unsuitable power supply
1b) Incorrect 

electrical

connections 

1c)  Engine  overload  protective

device cuts in.

1d) Blown or defective fuses
1e) Shaft blocked
1f) If  the  above  causes  have

already  been    checked,  the
engine may be malfunctioning

2a) Presence  of  solid  bodies  in

the pump rotor

2b) Bearings blocked

3a) Presence  of  air  inside  the

pump or suction tube

3b) Suction filter blocked

4a) Pipes  and  accessories  with

diameter  too  small  causing
excessive loss of head 

4b) Presence  of  deposits  or  solid

bodies in the internal passages
of the rotor suction filter

4c) Rotor deteriorated 
4d) Worn rotor and pump case
4e) Excessive viscosity of the liquid

pumped  (if other than water)

4f) Incorrect direction of rotation 

5a) Rotating part unbalanced 
5b) Worn bearings 
5c)  Pump  and  pipes  not  firmly
attached 
5d) Flow  too  strong  for  the

diameter of the delivery pipe 

5e) Unbalanced power supply 

6a) The  mechanical  seal  has

functioned  when  dry  or  has
stuck 

6b) Mechanical  seal  scored  by

presence  of  abrasive  parts  in
the liquid pumped 

11. Troubleshooting

WARNING:

Turn off the power supply before performing any operations.

Do not allow the pump or motor to run  when dry even for a short period
Strictly follow the user instructions and if necessary contact an authorised service centre

OFF

POSSIBLE REMEDIES

1a) Check that the mains frequency  and voltage correspond to the

electrical characteristics shown on the indicator plate

1b) Connect the power supply cable to the terminal board correctly.

Check that the thermal overload protection is  set correctly (see
data  on  the  engine  indicator  plate)  and  make  sure  that  the
fuseboard upline of the engine has been properly connected

1c) Check the power supply  and make sure that the pump shaft is

turning  freely.  Check  that  the  thermal  overload  protection  has
been set correctly (see engine indicator plate)

1d) Replace the fuses, check the electric power supply and points

a) and  c)

1e) Remove the cause of blockage as indicated in the “Blocked  pump”

instruction booklet

1f) Repair    or  replace  the  engine  by  applying  to  an  authorised

service centre

2a) If  possible,  dismantle  the  pump  casing    and  remove  any  solid

foreign  bodies  inside  the  rotor,    if  necessary  contact  an
authorised service centre 

2b) If  the  bearings  are  damaged  replace  them  or  if  necessary

contact an authorised service centre 

3a) Release  the  air  from  the  pump  using  the  pump  plugs  and/or

using  the  delivery  control  valve  .Repeat  the  filling  operations
until all air has been expelled 

3b) Clean the filter, if necessary, replace it . See point 2b) also.

4a) Use pipes and accessories suitable for the specific application 
4b) Clean  the  rotor  and  install  a  suction  filter  to  prevent  other

foreign bodies from entering 

4c) Replace  the  rotor,  if  necessary,  contact  an  authorised  service

centre 

4d) Replace the rotor and the pump casing 
4e) The pump is unsuitable 
4f) Invert the electrical connections on the terminal board  or control

panel 

5a) Check that no solid bodies are obstructing the rotor 
5b) Replace the bearings 
5c) Anchor the delivery and suction piping as needed 
5d) Use bigger diameters or reduce the pump flow
5e) Check that the mains voltage is right

In  cases  6a),  6b),  replace  the  seal,  if  necessary  contact  an
authorised service centre 
6a) Make sure that the pump casing is full of liquid and that all the air

has been expelled.

6b) Use a seal suited to the characteristics of the liquid being pumped.

Changes reserved.

IST GQ_GX_GM_07_2018R5_MXS 11_03con gall  09/07/18  09:06  Pagina 15

Summary of Contents for GQ

Page 1: ...aliano ORIGINAL OPERATING INSTRUCTIONS Page 9 English ORIGINAL BETRIEBSANLEITUNG Seite 16 Deutsch INSTRUCTIONS ORIGINALES POUR L UTILISATION Page 23 Fran ais INSTRUCCIONES ORIGINALES DE USO P gina 30...

Page 2: ...The maximum permissible structural working pressure Chapter 3 1 The type and section of the power cable Chapter 6 8 The type of electrical protection to be installed Chapter 6 8 1 1 Symbols To improve...

Page 3: ...d in explosive or flammable environments Improper use of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the saf...

Page 4: ...on and in order to fulfill the device requirements electrical supply etc It s Absolutely forbidden to install the machine in an environment with potentially explosive atmosphere 6 3 Unpacking Inspect...

Page 5: ...garden ponds and similar places a residual current device with I N not exceeding 30 mA must be installed in the supply circuit Install a device for disconnection from the mains switch with a contact...

Page 6: ...rician or to an expert techni cian Every maintenance operations cleaning or reparation executed with the electrical system under voltage it could cause serious injuries to people A possible replacemen...

Page 7: ...armaceutic use For the GMC GMV pumps a normal engine oil of the SAE 10W 30 type can also be used 9 DISPOSAL European Directive 2012 19 EU WEEE The final disposal of the device must be done by spe cial...

Page 8: ...erload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 9: ...11 70 12 71 12 1 71 12 2 75 12 3 76 79 1 CALPEDA S P A 2 3 CE 8 3 1 6 8 6 8 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 1 5 Calpeda S p...

Page 10: ...EDA 2 3 3 3 1 12 1 2900 3450rpm IPX8 240V 1 50 60 Hz 480V 3 50 60 Hz 70 dB A 75 dB A GQG 30 60 m 6 bar PN Pa Hmax Pa 4 4 1 CALPEDA S P A 4 2 4 3 4 4 4 5 5 12 1 i Made in Italy MONTORSO XXXXXXX Q min m...

Page 11: ...h min mm mm GQR GQS GQV GQS GQV GQS GQV GQS GQV GQS GQV mm h min h max 225 240 240 265 285 315 330 330 355 375 h max h min min 300 x 250 3 93 037 3 GQRM 10 10 GF GQRM 10 12 GF GQRM 10 14 GF GQRM 10 16...

Page 12: ...RN8 F 12 2 6 8 2 GQG H07 RN8 F 6 8 3 GQR GQN GQS GQV GXC GXV GQG D 6 8 4 GMC GMV D 12 2 7 7 1 7 2 GQG 35 GQR GQN GQS GQG GQV 7 3 6 5 8 CALPEDA CALPEDA S P A 8 1 ON OFF OFF i i OFF IST GQ_GX_GM_07_2018...

Page 13: ...33 12 50 12 52 12 60 14 00 14 14 O 14 15 14 20 14 22 14 24 14 46 14 47 14 80 15 50 15 70 28 00 28 04 28 08 28 20 34 03 34 04 34 05 34 08 34 09 34 12 34 13 36 00 40 00 64 08 64 12 O 70 00 70 05 O 70 08...

Page 14: ...2 3 4 5 6 1a 1b 1c 1d 1e 1f 2a 2b 3a 3b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 1a 1b 1c 1d a c 1e 2 1f 2a 2b 3a 3b 2b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 6a 6b IST GQ_GX_GM_07_2018R5_MXS 11_03con...

Page 15: ...0 220 245 265 265 295 h min GQR M 10 16 GQR M 10 18 GQR 10 20 GQRM 10 20 kg GQRM 15 15 5 15 5 18 19 20 5 fM GQR GQR M 10 32 10 395 410 410 435 455 455 485 14 7 15 2 15 2 16 7 18 3 19 7 GQR M 10 32 12...

Page 16: ...0 G1 1 2 ISO 228 fM mm mm kg GXV 10 1 11 7 11 7 11 7 13 2 13 2 GXV M 40 7 433 GXV M 40 8 458 508 533 248 273 458 GXV M 40 9 533 273 GXVM kg GXC 10 1 11 7 11 7 13 2 GXC M 40 10 433 GXC M 40 13 458 508...

Page 17: ...543 568 588 588 618 308 328 328 358 On Off kg h min h max 50 DN 50 90 fM 89 94 242 430 452 G 2 ISO 228 GQV 15 15 2 16 19 20 5 16 16 2 18 20 5 22 GQV M 50 8 GQV M 50 9 460 535 535 275 275 485 GQV M 50...

Page 18: ...2 2 PN 10 2 GMC 50CE GMC 50BE GMC 50AE GMCM 50CE GMCM 50BE 28 29 30 5 28 29 5 kg GMV 50CE GMV 50BE GMV 50AE GMVM 50CE GMVM 50BE 27 28 29 5 27 28 5 kg GMC 50 65C GMC 50 65B GMC 50 65A GMCM 50 65C GMCM...

Page 19: ...ator coil Zum Schutzrelais f r Thermo Schutzschalter Protecteurs thermiques vers la bobine du contacteur Termoprotectores a conectar a la bobina del contactor 4 67 380 nero black schwarz noir negro sv...

Page 20: ...96 09 76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 28 04 GQV 50 GQR GQR 10 GQR 10 32 14 80 14 00 28 04 GQN 50 GQS 50 14 80 14 00 12 3 Disegno per lo smontaggio ed il r...

Page 21: ...76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 GXC GXV 28 04 14 00 12 00 12 21 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeic...

Page 22: ...20 76 64 82 04 81 00 78 00 76 00 94 12 94 04 94 00 14 24 14 00 28 00 28 04 12 00 96 09 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Demontage und...

Page 23: ...ektiv 2006 42 EC 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar GX GX M GQ GQ M GM GM M pumptyp och serienummer visade p nam...

Page 24: ...tification de la pompe submerg e enlever l tiquette avec le code barre du carton d emballage et l appliquer ici Para facilitar la identificaci n de la bomba sumergida cortar la etiqueta con el c digo...

Reviews: