background image

Page 11 / 80

GQ, GX, GM Rev. 5 - Operating Instructions

GB

Use  only  original  spare  parts  provided  from
Calpeda  S.p.A  or  from  an  authorized
distributor.

Don't remove or change the labels placed on
the device. 

Do  not  start  the  device  in  case  of  defects  or
damaged parts.

Maintenance  operations,  requiring  full  or
partial  disassembly  of  the  device,  must  be
done only after disconnection from the supply.
Pollution  of  the  liquid  could  occur  due  to
leakage of lubricants.

4.2 Safety devices

The  device  has  an  external  case  that  prevents  any
contact with internal parts.

4.3 Residual risks

The  appliance,  designed  for  use,  when  used  in-line
with  the  design  and  safety  rules,  doesn't  have  resi-
dual risks.

4.4 Information and Safety signals

For this kind of product there will not be any signals
on the product.

4.5 Individual protection devices

During  installation,  starting  and  maintenance  it  is
suggested to the authorized operators to consider  the
use  of  individual  protection  devices  suitable  for
described activities.
During ordinary and extraordinary maintenance inter-
ventions,  where  it  is  required  to  remove  the  filter,
safety gloves are required.

Signal  individual protection device

HAND PROTECTION
(gloves for protection against chemical, ther-
mal and mechanical risks).

5. TRANSPORTATION AND HANDLING

The product is packed to maintain the content intact.
During  transportation  avoid  to  stack  excessive  wei-
ghts.  Ensure  that  during  the  transportation  the
packed cannot move.
The  transport  vehicles  must  comply,  for  the  weight
and  dimensions,  with  the  chosen  product  (see  para-
graph 12.1 dimensions and weights).

5.1 Handling 

Handle  with  care,  the  packages  must  not  receive
impacts.
Avoid  to  impact  onto  the  package  materials  that
could damage the pump.
If  the  weight  exceeds  25  Kg  the  package  must  be
handled  by  two  person  at  the  same  time  (see  para-
graph 12.1 dimensions and weights).

6 INSTALLATION

6.1 Dimensions

For  the  dimensions  of  the  device  refer  to  the  annex
"Dimensions" (paragraph 12.1 Annexes).

6.2 Ambient  requirements  and  installation  site

dimensions

The  customer  has  to  prepare  the  installation  site  in
order to guarantee the right installation and in order to
fulfill the device requirements (electrical supply, etc...).

It's  Absolutely  forbidden  to  install  the  machine  in  an
environment with potentially explosive atmosphere.

6.3 Unpacking

Inspect  the  device  in  order  to  check  any
damages  which  may  have  occurred  during
transportation.

Package  material,  once  removed,  must  be  discar-
ded/recycled  according  to  local  laws  of  the  destina-
tion country.

6.4. Pipes

The internal diameter of the delivery pipe must never
be smaller than the diameter of the pump connection
port:

G 1

1

/

2

(DN 32 PN6) for 

GQG

;

G 1

1

/

2

(DN 40) for 

GXC, GXV, GQR

G 2

(DN 50) for 

GMC 50,GMV 50, GQN, GQS, GQV

;

DN 65  for 

GMC 50-65, GMV 50-65

ATTENTION:  The  pump  must  be  lifted  and
transported using the handle fitted for this purpose
and not pulled by the electrical power cable.

Place  the  pump,  with  vertical  axis,  at  the  bottom  of
the pit or at the site of installation.

6.5. Stationary installation

6.5.1. Stationary 

installation 

with 

vertical

magnetic float switch

Installation fit a check valve against back flow in the
delivery pipe ball valve (swing valve for GQR).
Provide  for  the  possibility  of  removing  the  pump
without  having  to  drain  the  entire  system  (if
necessary, fit a gate valve and a union coupling).
With the pump in the resting position secure the delivery
pipe to a rest, suitable for its length and weight.
If  slime  deposits  are  expected  to  form  at  the  bottom
of  the  installation  pit,  a  support  must  be  provided  to
keep the pump raised.

i

min 550 x 550

3.93.037/3

h

max

h

min

mm

h

min

h

max

h

min

h

max

205

220

220

245

265

265

410

425

425

450

470

470

GQR 10-10

GQR 10-12

GQR 10-14

GQR 10-16

GQR 10-18

GQR 10-20

mm

h

min

h

max

mm

mm

mm

3.93.004/1

GQR

GQS, GQV 50-9

GQS, GQV 50-10

515

530

260

275

GQS, GQV 50-11

555

300

GQS, GQV 50-13

575

320

320 575

GQS, GQV 50-15

GMC 50...

GMV 50...

500

500

180

180

GMC 50-65..

505

185

GMC 50-65..

505

185

mm

h

min

h

max

225
240
240
265
285

315
330
330
355
375

h

max

h

min

min 300 x 250

3.93.037/3

GQRM 10-10 GF
GQRM 10-12 GF
GQRM 10-14 GF
GQRM 10-16 GF
GQRM 10-18 GF

GXV

(M)

 40-7

GXV

(M)

 40-8

508
533

248
273

GXV

(M)

 40-9

533 273

GXC

(M)

 40-10

GXC

(M)

 40-13

508
533

248
273

M

1

4.67.380

h

max

h

min

h

max

h

min

On

Off

min 550 x 550

3.93.037/3

h

max

h

min

mm

h

min

h

max

h

min

h

max

205

220

220

245

265

265

410

425

425

450

470

470

GQR 10-10

GQR 10-12

GQR 10-14

GQR 10-16

GQR 10-18

GQR 10-20

mm

h

min

h

max

mm

mm

mm

3.93.004/1

GQR

GQS, GQV 50-9

GQS, GQV 50-10

515

530

260

275

GQS, GQV 50-11

555

300

GQS, GQV 50-13

575

320

320 575

GQS, GQV 50-15

GMC 50...

GMV 50...

500

500

180

180

GMC 50-65..

505

185

GMC 50-65..

505

185

mm

h

min

h

max

225
240
240
265
285

315
330
330
355
375

h

max

h

min

min 300 x 250

3.93.037/3

GQRM 10-10 GF
GQRM 10-12 GF
GQRM 10-14 GF
GQRM 10-16 GF
GQRM 10-18 GF

GXV

(M)

 40-7

GXV

(M)

 40-8

508
533

248
273

GXV

(M)

 40-9

533 273

GXC

(M)

 40-10

GXC

(M)

 40-13

508
533

248
273

M

1

4.67.380

h

max

h

min

h

max

h

min

On

Off

IST GQ_GX_GM_07_2018R5_MXS 11_03con gall  09/07/18  09:06  Pagina 11

Summary of Contents for GQ

Page 1: ...aliano ORIGINAL OPERATING INSTRUCTIONS Page 9 English ORIGINAL BETRIEBSANLEITUNG Seite 16 Deutsch INSTRUCTIONS ORIGINALES POUR L UTILISATION Page 23 Fran ais INSTRUCCIONES ORIGINALES DE USO P gina 30...

Page 2: ...The maximum permissible structural working pressure Chapter 3 1 The type and section of the power cable Chapter 6 8 The type of electrical protection to be installed Chapter 6 8 1 1 Symbols To improve...

Page 3: ...d in explosive or flammable environments Improper use of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the saf...

Page 4: ...on and in order to fulfill the device requirements electrical supply etc It s Absolutely forbidden to install the machine in an environment with potentially explosive atmosphere 6 3 Unpacking Inspect...

Page 5: ...garden ponds and similar places a residual current device with I N not exceeding 30 mA must be installed in the supply circuit Install a device for disconnection from the mains switch with a contact...

Page 6: ...rician or to an expert techni cian Every maintenance operations cleaning or reparation executed with the electrical system under voltage it could cause serious injuries to people A possible replacemen...

Page 7: ...armaceutic use For the GMC GMV pumps a normal engine oil of the SAE 10W 30 type can also be used 9 DISPOSAL European Directive 2012 19 EU WEEE The final disposal of the device must be done by spe cial...

Page 8: ...erload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 9: ...11 70 12 71 12 1 71 12 2 75 12 3 76 79 1 CALPEDA S P A 2 3 CE 8 3 1 6 8 6 8 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 1 5 Calpeda S p...

Page 10: ...EDA 2 3 3 3 1 12 1 2900 3450rpm IPX8 240V 1 50 60 Hz 480V 3 50 60 Hz 70 dB A 75 dB A GQG 30 60 m 6 bar PN Pa Hmax Pa 4 4 1 CALPEDA S P A 4 2 4 3 4 4 4 5 5 12 1 i Made in Italy MONTORSO XXXXXXX Q min m...

Page 11: ...h min mm mm GQR GQS GQV GQS GQV GQS GQV GQS GQV GQS GQV mm h min h max 225 240 240 265 285 315 330 330 355 375 h max h min min 300 x 250 3 93 037 3 GQRM 10 10 GF GQRM 10 12 GF GQRM 10 14 GF GQRM 10 16...

Page 12: ...RN8 F 12 2 6 8 2 GQG H07 RN8 F 6 8 3 GQR GQN GQS GQV GXC GXV GQG D 6 8 4 GMC GMV D 12 2 7 7 1 7 2 GQG 35 GQR GQN GQS GQG GQV 7 3 6 5 8 CALPEDA CALPEDA S P A 8 1 ON OFF OFF i i OFF IST GQ_GX_GM_07_2018...

Page 13: ...33 12 50 12 52 12 60 14 00 14 14 O 14 15 14 20 14 22 14 24 14 46 14 47 14 80 15 50 15 70 28 00 28 04 28 08 28 20 34 03 34 04 34 05 34 08 34 09 34 12 34 13 36 00 40 00 64 08 64 12 O 70 00 70 05 O 70 08...

Page 14: ...2 3 4 5 6 1a 1b 1c 1d 1e 1f 2a 2b 3a 3b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 1a 1b 1c 1d a c 1e 2 1f 2a 2b 3a 3b 2b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 6a 6b IST GQ_GX_GM_07_2018R5_MXS 11_03con...

Page 15: ...0 220 245 265 265 295 h min GQR M 10 16 GQR M 10 18 GQR 10 20 GQRM 10 20 kg GQRM 15 15 5 15 5 18 19 20 5 fM GQR GQR M 10 32 10 395 410 410 435 455 455 485 14 7 15 2 15 2 16 7 18 3 19 7 GQR M 10 32 12...

Page 16: ...0 G1 1 2 ISO 228 fM mm mm kg GXV 10 1 11 7 11 7 11 7 13 2 13 2 GXV M 40 7 433 GXV M 40 8 458 508 533 248 273 458 GXV M 40 9 533 273 GXVM kg GXC 10 1 11 7 11 7 13 2 GXC M 40 10 433 GXC M 40 13 458 508...

Page 17: ...543 568 588 588 618 308 328 328 358 On Off kg h min h max 50 DN 50 90 fM 89 94 242 430 452 G 2 ISO 228 GQV 15 15 2 16 19 20 5 16 16 2 18 20 5 22 GQV M 50 8 GQV M 50 9 460 535 535 275 275 485 GQV M 50...

Page 18: ...2 2 PN 10 2 GMC 50CE GMC 50BE GMC 50AE GMCM 50CE GMCM 50BE 28 29 30 5 28 29 5 kg GMV 50CE GMV 50BE GMV 50AE GMVM 50CE GMVM 50BE 27 28 29 5 27 28 5 kg GMC 50 65C GMC 50 65B GMC 50 65A GMCM 50 65C GMCM...

Page 19: ...ator coil Zum Schutzrelais f r Thermo Schutzschalter Protecteurs thermiques vers la bobine du contacteur Termoprotectores a conectar a la bobina del contactor 4 67 380 nero black schwarz noir negro sv...

Page 20: ...96 09 76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 28 04 GQV 50 GQR GQR 10 GQR 10 32 14 80 14 00 28 04 GQN 50 GQS 50 14 80 14 00 12 3 Disegno per lo smontaggio ed il r...

Page 21: ...76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 GXC GXV 28 04 14 00 12 00 12 21 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeic...

Page 22: ...20 76 64 82 04 81 00 78 00 76 00 94 12 94 04 94 00 14 24 14 00 28 00 28 04 12 00 96 09 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Demontage und...

Page 23: ...ektiv 2006 42 EC 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar GX GX M GQ GQ M GM GM M pumptyp och serienummer visade p nam...

Page 24: ...tification de la pompe submerg e enlever l tiquette avec le code barre du carton d emballage et l appliquer ici Para facilitar la identificaci n de la bomba sumergida cortar la etiqueta con el c digo...

Reviews: